2237 (6158.04) - DEC

Case IH 2237 (6158.04) - DEC – Transmission Controller (TCU): Synchro 7 Solenoid - short to GND

Issue description

A short to ground on the circuit for the Synchro 7 Solenoid, meaning the voltage supply or control wire is shorting directly to the chassis ground. This prevents the solenoid from operating correctly, which can lead to transmission slipping, failure to shift, or the transmission controller disabling certain gears.

Applies to these machines

  • MAXXUM T4E
  • Quadtrac
  • Quadtrac 450
  • Steiger

Check the cause

  1. Inspect the transmission harness for damaged wiring that may be rubbing against the chassis and shorting to ground

  2. Test the Synchro 7 solenoid coil for an internal short or failure

  3. Check the TCU and solenoid connectors for loose connections, moisture, or bent pins

  4. If the wiring and solenoid test within specification, check the Transmission Controller (TCU) for an internal failure

Repair steps

  1. Identify the physical location of the Synchro 7 solenoid on the transmission valve manifold.

  2. Disconnect the electrical harness and use a multimeter to verify if the short is in the harness or the solenoid itself.

  3. Repair the damaged section of the wiring harness, or replace the solenoid valve assembly if the coil has failed internally.

Parts you might need

(3)
  • 12V Transmission Solenoid

    87456901

    Replaces 190432A1

  • Transmission Valve Assembly with Solenoids

    118872A1

    or 1986629C1; Fits Quadtrac and Magnum models

  • Transmission Control Solenoid Valve

    110415A1

    Replaces 349296A1