Case IH 2243 (519182.04) - DEC – DEC (TCU): Synchro 8 Solenoid - short to GND
Issue description
The electrical circuit controlling the "Synchro 8" transmission solenoid has shorted to ground.
Applies to these machines
5 machines- MAXXUM T4E
- CX series
- MX series
- MC series
- MTX series
Check the cause
Inspect the wiring harness for areas where wire insulation may have rubbed through, causing a direct short to the chassis (ground)
Check the electrical connector at the Synchro 8 solenoid for loose connections or bent pins
Test the internal coil of the Synchro 8 solenoid to see if it has shorted out
Check the Transmission Control Unit (TCU) for an internal failure if the wiring and solenoid are intact
Repair steps
Locate the Synchro 8 Solenoid
Find the solenoid valve block on the transmission.
Inspect the Connector
Disconnect the harness from the Synchro 8 solenoid. Check for loose, corroded, or bent pins.
Test the Wiring Harness
Trace the wiring back to the TCU. Use a multimeter to test for continuity to ground. If a short to ground is found in the harness, repair or replace the damaged wiring section.
Test the Solenoid Coil
Test the solenoid coil for an internal short. If the coil has failed, it must be replaced.
Evaluate the TCU
If the connector, wiring harness, and solenoid coil all test perfectly fine, the TCU may require replacement or reprogramming due to an internal failure.
Parts you might need
(2)Powershift / Synchro Solenoid Coil
84259238Replaces older part number 298614A1
Solenoid assembly
349295A1The solenoid coil fits into this assembly