Case IH 2284-02 - UCM – UCM: Vehicle controller loss of communication with front pilot head #1
Issue description
The UCM is no longer receiving or transmitting data to the specific pilot head over the CAN network, indicating a CAN bus failure.
Applies to these machines
7 machines- MAGNUM AFS Connect
- Case IH Puma 180-260 CVX
- T7.220
- T7.235
- T7.250
- T7.260
- T7.270
Check the cause
Inspect CAN bus 2 wiring harness between the UCM controller and the front pilot head actuator for open circuits or shorts
Check connectors on CAN bus 2 for damaged pins, corrosion, or loose connections
Verify voltage levels on CAN bus 2 to rule out wiring issues before condemning the module
Repair steps
Replace the faulty pilot head component
Replace the faulty pilot head component if the repair ultimately requires it.
Perform a valve calibration
You must perform a valve calibration whenever a new valve pilot head is installed.
Connect a pressure transducer
Connect a pressure transducer (Special Tool #380001903) using a jumper harness (Special Tool #84148258) to perform the on-board calibration.
Navigate through the H Menu
Navigate through the 'H Menu' on the display to access the calibration channels and complete the setup.
Parts you might need
(4)Valve Pilot Head
UCM Controller
Pressure Transducer
380001903Special Tool
Jumper Harness
84148258Special Tool
Get help to fix this fault by requesting a quote