Case IH 2295-03 - UCM – UCM: Front pilot head #2 reporting supply voltage high
Issue description
The electronic control system is detecting a voltage reading above the acceptable operational limit at the pilot head of the hydraulic remote control valve (EHR valve). This is typically caused by a short circuit to power in the wiring harness, a sticking power supply relay, or an internal electrical failure within the pilot head solenoid itself.
Applies to these machines
3 machines- MAGNUM AFS Connect
- Case IH Magnum AFS Connect Series
- Case IH Steiger AFS Connect Series
Check the cause
Inspect the UCM interface wire harness and the specific branch running to the front remote valves for chafed wires that may be shorting to a 12V power source.
Disconnect the electrical terminal pin at the pilot head and check for water ingress, bent pins, or corrosion.
Check the UCM power supply relays in the fuse box, specifically testing the UCM Afterrun power supply relay (K-032) to ensure it is not stuck closed and feeding improper voltage.
Swap the suspect pilot head with a known-good pilot head from an adjacent remote valve; if the fault code changes to match the new position, the pilot head has failed internally, but if the code remains on #2, the issue is in the UCM or the wiring harness.
Repair steps
Depressurize and Power Down
Ensure the tractor is turned off, hydraulic pressure is relieved, and the battery is disconnected to prevent electrical spikes.
Remove the Faulty Pilot Head
Locate the front remote valve stack. Disconnect the electrical connector from pilot head #2. Remove the mounting hardware (typically M8 x 40mm hex socket screws) and carefully pull the pilot head and adapter plate away from the valve body.
Install the New Part
Install the replacement pilot head assembly. Secure it using the hex socket screws and reconnect the electrical harness.
Perform Valve Calibration
Connect a pressure transducer (Special Tool # 380001903) and jumper harness (Special Tool # 84148258) to the valve. Use the Electronic Service Tool (EST) or access the tractor's on-board ADIC 'H Menu' (Calibration Menu) to run the automated calibration procedure for the remote valves so the UCM can learn the new pilot head's electrical characteristics.
Parts you might need
(5)Valve Pilot Head Assembly
51456399Fitment: Magnum AFS Connect remote control valves
Hex Socket Screw (M8 x 40mm, Class 8.8)
16690925Replaces older #864-8040; used to mount the pilot head
UCM Afterrun Power Supply Relay (12V, 40A Mini)
84543666UCM Interface Wire Harness
48131350If the harness is shorted
Universal Control Module (UCM)
47632823Only required if the module itself has suffered an internal hardware short
Get help to fix this fault by requesting a quote