Case IH 2418 – Transmission Control Unit: Low / high range synchronizer potentiometer - voltage too low
Issue description
The transmission control system is receiving a voltage signal from the low/high range synchronizer potentiometer that falls below the minimum calibrated threshold. This typically points to a wiring issue, a disconnected harness, or a failure of the potentiometer itself.
Applies to these machines
6 machines- Optum
- Magnum MX210
- Magnum MX230
- Magnum MX255
- Magnum MX285
- Puma
Check the cause
Verify that the tractor battery has not been connected to an external power supply (like a jump starter). If it is, disconnect it and test the system for normal operation.
Inspect the low/high range synchronizer potentiometer connector (X-666) and the CCU connector (X-097). Ensure they are securely connected, undamaged, pins are in the correct position, and the fit is tight.
Disconnect connector X-666. Turn the ignition switch ON. Measure the voltage between connector X-666 pin 3 (wire 7525G - Green) and a good ground. If it does not read approximately 5 Volts, the wire harness needs repair or replacement.
Measure between connector X-666 pin 1 (wire 60BT - Black/White) and ground. If an open circuit is indicated, repair the harness.
Turn the ignition OFF. Disconnect connector X-956. Measure continuity between connector X-666 pin 2 (wire 7960 - Violet) and connector X-956 pin 18 (wire 7960 - White). If an open circuit is found, repair the harness.
Turn the ignition ON. Measure the voltage between connector X-666 pin 2 (wire 7960 - Violet) and ground. If any voltage is indicated, there is a short to power in the harness that must be repaired.
Repair steps
Replace the Sensor
Remove and replace the low/high range synchronizer potentiometer.
Recalibrate/Test
Clear the fault codes and test the transmission by shifting through the ranges to ensure the synchronizer engages properly and the code does not return.
Software Update
If the fault is still present after replacing the potentiometer, download/flash the correct level of software to the transmission controller.
Module Replacement
If the fault recurs even after a software update and sensor replacement, the UCM (Unit Control Module) is likely internally faulted and must be removed and replaced.
Parts you might need
(1)Low / High Range Synchronizer Potentiometer
I114255A2Exact part numbers vary heavily based on the specific tractor series and serial number breaks. I114255A2 is a generic hydraulic control potentiometer for older Magnums.
Get help to fix this fault by requesting a quote