Case IH 2426-04 - UCM – UCM: Auto depth control position feedback voltage high
Issue description
The control module is receiving a voltage signal from the depth control position sensor that exceeds the expected normal operating range (often caused by a short to power or a faulty potentiometer).
Applies to these machines
1 machine- MAGNUM AFS Connect
Check the cause
Inspect the auto depth control position sensor (rotary potentiometer) for physical damage or water ingress
Check the wiring harness between the depth control position sensor and the UCM for chafing, pinched wires, or melted insulation that could cause a short to a high-voltage source (if voltage is high) or a short to ground/open circuit (if voltage is low)
Verify the reference voltage (usually 5V) and ground at the sensor connector
Ensure the connectors at the Universal Control Module (UCM) are fully seated and free of corrosion
Repair steps
Disconnect battery power
Disconnect battery power before servicing the UCM or sensor circuits.
Repair or replace wiring harness
Repair or replace any damaged sections of the wiring harness between the sensor and the UCM.
Remove faulty sensor
If the wiring tests good, remove the faulty auto depth control position sensor from its mounting bracket.
Install new sensor
Install the new sensor and ensure the mechanical linkage is properly aligned so the sensor sweeps through its correct physical range.
Clear codes and recalibrate
Reconnect the harness and use a Case IH Electronic Service Tool (EST) or the AFS Pro monitor to clear the UCM fault codes and recalibrate the auto depth control limits.
Parts you might need
(1)Auto Depth Control Position Sensor
Must be compatible with the UCM on Case IH Magnum AFS Connect models.