2426-04 - UCM

Case IH 2426-04 - UCM – UCM: Auto depth control position feedback voltage high

Issue description

The control module is receiving a voltage signal from the depth control position sensor that exceeds the expected normal operating range (often caused by a short to power or a faulty potentiometer).

Applies to these machines

  • MAGNUM AFS Connect

Check the cause

  1. Inspect the auto depth control position sensor (rotary potentiometer) for physical damage or water ingress

  2. Check the wiring harness between the depth control position sensor and the UCM for chafing, pinched wires, or melted insulation that could cause a short to a high-voltage source (if voltage is high) or a short to ground/open circuit (if voltage is low)

  3. Verify the reference voltage (usually 5V) and ground at the sensor connector

  4. Ensure the connectors at the Universal Control Module (UCM) are fully seated and free of corrosion

Repair steps

  1. Disconnect battery power

    Disconnect battery power before servicing the UCM or sensor circuits.

  2. Repair or replace wiring harness

    Repair or replace any damaged sections of the wiring harness between the sensor and the UCM.

  3. Remove faulty sensor

    If the wiring tests good, remove the faulty auto depth control position sensor from its mounting bracket.

  4. Install new sensor

    Install the new sensor and ensure the mechanical linkage is properly aligned so the sensor sweeps through its correct physical range.

  5. Clear codes and recalibrate

    Reconnect the harness and use a Case IH Electronic Service Tool (EST) or the AFS Pro monitor to clear the UCM fault codes and recalibrate the auto depth control limits.

Parts you might need

(1)
  • Auto Depth Control Position Sensor

    Must be compatible with the UCM on Case IH Magnum AFS Connect models.

Get help to fix this fault by requesting a quote