Case IH 2518 – UCM / CCU: F2/R1 synchronizer potentiometer - signal too low

Issue description

The voltage signal returning from the F2/R1 synchronizer position sensor (potentiometer) to the control module has dropped below the acceptable minimum threshold, indicating a potential open circuit, short to ground, or a failed sensor.

Applies to these machines

  • Optum
  • Case IH Puma 165
  • Case IH Puma 180
  • Case IH Puma 195
  • Case IH Puma 210
  • Case IH Puma 225
  • Case IH Puma CVX
  • Case IH MX Series
  • Case IH TG Series

Check the cause

  1. Inspect the electrical connector at the F2/R1 synchronizer potentiometer for corrosion, moisture, backed-out pins, or poor terminal tension.

  2. Test the wiring harness between the potentiometer and the UCM/CCU for an open circuit or a short circuit to ground.

  3. Measure the resistance/voltage sweep of the F2/R1 synchronizer position sensor to check for internal failure or dead spots.

  4. If the sensor and wiring harness test perfectly, check the UCM/CCU for faults (least common failure mode).

Repair steps

  1. Power down the tractor and disconnect the battery

    Power down the tractor and disconnect the battery to prevent electrical shorts during repair.

  2. Locate the F2/R1 synchronizer potentiometer

    Locate the F2/R1 synchronizer potentiometer on the transmission housing (often denoted as sensor X533 or X534 in CNH electrical schematics).

  3. Disconnect the wiring harness connector

    Disconnect the wiring harness connector from the potentiometer.

  4. Extract the old potentiometer

    If diagnostic tests proved the sensor is faulty, remove the retaining hardware and extract the old potentiometer from the synchronizer assembly.

  5. Install the new OEM potentiometer

    Install the new OEM potentiometer and secure it with the mounting hardware.

  6. Reconnect the wiring harness

    Reconnect the wiring harness, ensuring the connector clicks securely into place.

  7. Reconnect the battery

    Reconnect the battery.

  8. Clear the 2518 error code

    Using the tractor's integrated control panel or an electronic service tool (EST), clear the 2518 error code from the UCM.

  9. Test the system for normal operation

    Test the system for normal operation by shifting through the F2 and R1 ranges to ensure the synchronizer engages properly and the code does not return.

Parts you might need

(3)
  • Synchronizer Potentiometer / Position Sensor

    87685207

    Fits Case IH Puma series (165, 180, 195, 210, 225) and equivalent New Holland models.

  • Synchronizer mechanical assembly

    K5186629

    Entire synchronizer mechanical assembly used on older utility models.

  • Synchronizer mechanical assembly

    5186629

    Entire synchronizer mechanical assembly used on older utility models.

Get help to fix this fault by requesting a quote

Browse other Case IH codes