Case IH 2569 – UCM (Universal Control Module): Gear pump (hydro filter) - high pressure warning
Issue description
The system has detected abnormally high pressure at the hydrostatic gear pump filter. The primary failure mode is typically a faulty hydro filter pressure sensor (charge pressure sensor).
Applies to these machines
7 machines- Optum
- Case IH Puma 150
- Case IH Puma 165
- Case IH Puma 185
- Case IH Puma 200
- Case IH Puma 220
- Case IH Puma 240
Check the cause
Check for concurrent codes; if no other error code is displayed, proceed with diagnostics
Verify that the tractor battery power supply has not been connected to an external power supply (like a jump starter or external charger). Disconnect if present and test for normal operation
Inspect the hydro filter pressure sensor (charge pressure sensor) connector (e.g., X-523 or X-916) and the UCM controller connector (e.g., X-955)
Verify pin fitment to ensure the connectors are fully seated, not damaged, pins are in the correct position, and the fit is tight
Disconnect the sensor connector and check for a +5 Volt reference signal coming from the UCM
Repair steps
Repair Wiring
If a fault is indicated during the connector and voltage checks, repair or replace the wiring harness/connector as required.
Replace Sensor
If the wiring and voltage are good, the hydro filter pressure sensor (charge pressure sensor) is likely faulty and should be replaced.
Clear and Test
Once the cause of the error code has been rectified, clear the error code from the UCM and test the hydraulic system for normal operation.
Software Update
If the fault is still present after replacing the sensor, download the correct/latest level of software to the UCM.
Replace UCM
If the fault recurs after verifying the sensor, wiring, and software, remove and replace the Universal Control Module (UCM).
Parts you might need
(3)Hydro filter pressure sensor (Charge pressure sensor)
OEM part number varies by specific chassis/serial; primary component responsible for false high-pressure readings.
Universal Control Module (UCM)
Required only if the controller has internally failed and cannot process the sensor signal.
Hydrostatic Gear Pump Filter
Generic replacement part. A severely restricted filter can cause genuine high-pressure conditions.