Case IH 2622 (6153.18) - DEC – DEC: Synchro 2/4 or 6/8 disengage error
Issue description
The transmission's synchronizer for gears 2/4 or 6/8 is failing to disengage properly. The control module is receiving a valid signal from the synchronizer position sensor, but the value is below the expected normal operating threshold.
Applies to these machines
1 machine- MAXXUM T4E
Check the cause
Check the transmission oil temperature and pressure sensors to ensure the fluid is at operating parameters.
Run a transmission calibration procedure to see if the synchronizer can successfully relearn its engagement/disengagement positions.
Check the wiring harness and connectors for the synchronizer position transducers and shift solenoids for shorts or open circuits.
Parts you might need
(4)Transmission Synchronizer 2 Assembly
Synchro 2/4 or 6/8 hub and sleeve
Synchronizer Rings
Synchronizer Position Transducer / Sensor
Shift Fork / Actuator Solenoid
Get help to fix this fault by requesting a quote