Case IH 2666-02 - ACM – ACM: Joystick y-axis lever forward positive position status circuit fault
Issue description
The control system has detected an electrical anomaly (such as a short circuit, open circuit, or out-of-range voltage) in the circuit that monitors the forward (positive) movement of the joystick's Y-axis.
Applies to these machines
7 machines- MAGNUM AFS Connect
- Case IH Magnum AFS Connect
- Case IH Magnum Series
- Case IH Puma Series
- Case IH Maxxum Series
- Case IH Optum Series
- Case IH Steiger Series
Check the cause
Verify ACM Configuration using the Electronic Service Tool (EST) to ensure incorrect configuration isn't falsely triggering the fault
Monitor the Y-axis position voltages for signals indicating voltage too low, voltage too high, or an open/short circuit
Inspect the wiring harness and connectors between the joystick assembly and the ACM for continuity, pinched wires, open circuits, or shorts to ground/battery
Check for loss of communication between the ACM and the instrumentation controller
Repair steps
Connect diagnostic tool
Connect the CNH Electronic Service Tool (EST) to the machine's diagnostic port to confirm 2666-02 is active and review any freeze-frame data.
Verify configuration
Navigate to the ACM configuration menu to ensure the correct joystick type is programmed for the tractor.
Inspect connector
Disconnect the multi-pin CNH plug at the base of the joystick. Inspect the pins for corrosion, moisture, or damage.
Test wiring harness
Use a multimeter to test the wiring harness from the joystick connector back to the Armrest Control Module (ACM) for continuity and shorts.
Diagnose joystick failure
If the wiring harness tests good and the ACM is configured correctly, the internal Y-axis potentiometer/sensor inside the joystick has failed.
Remove faulty joystick
Remove the armrest control panel trim and unbolt the faulty joystick assembly.
Install replacement joystick
Install the replacement joystick, reconnect the harness, and reassemble the armrest.
Clear codes and calibrate
Clear the fault codes using the EST and perform a joystick calibration procedure to map the new X and Y axis limits to the ACM.
Parts you might need
(8)Electronic Joystick Control Assembly
84219586Multi-axis proportional joystick. Replaces older numbers 84312459, 84521033, and 87598211. Fits Puma, Maxxum, Optum, and New Holland T7 series.
Case IH Joystick
84128474Case IH Joystick
47450759Case IH Joystick
47471126Remanufactured Joystick
90493664RFits Maxxum 115-145
Remanufactured Joystick
47372893RArmrest Control Module
47443335Remanufactured version: 47443335R
Electronic Control Unit for Armrest Control Module
48068685
Get help to fix this fault by requesting a quote