Case IH 2712 – ZTC: ZTC - CAN message PTCTL2 signal TLOP error or not available
Issue description
The fault indicates a Controller Area Network (CAN) bus communication error. Specifically, the PTCTL2 (Powertrain Control 2) message, which carries the TLOP (Transmission Lubrication Oil Pressure) signal, is experiencing a timeout, is invalid, or is completely unavailable on the network. This means the control system is not receiving the required transmission lubrication oil pressure data to safely monitor and operate the transmission.
Applies to these machines
2 machines- Steiger T4B
- Steiger
Check the cause
Check the CAN bus wiring harness for broken wires, defective connectors, or open circuits between the transmission sensors, the engine controller, and the ZTC module.
Test the CAN network for short circuits to vehicle ground or battery voltage, which can cause interference and message timeouts.
Verify the physical Transmission Lubrication Oil Pressure sensor and its supply voltage to ensure it is not electrically defective.
Repair steps
Locate the break or short in the wiring harness
Locate the break or short in the wiring harness between the TLOP sensor and the ZTC.
Repair the damaged wire/connector
Repair the damaged wire or connector found during the harness inspection.
Replace the Transmission Lubrication Oil Pressure sensor
Replace a failed Transmission Lubrication Oil Pressure sensor if it is internally shorted.
Parts you might need
(3)Transmission Lubrication Oil Pressure Sensor
Generic Part
CAN Bus Wiring Harness / Pigtail Connectors
Generic Part
ZTC Controller / Main CVT Controller
Generic Part