Case IH 2763 (3042.19) - DEC – UCM: Open circuit on Reverse solenoid (HSD)
Issue description
The control module has detected an open circuit on the High Side Driver (HSD) line supplying the reverse directional solenoid.
Applies to these machines
9 machines- MAXXUM T4E
- Case 21F
- Case 121F
- Case 221F
- Case 321F
- Case W50C
- Case W60C
- Case W70C
- Case W80C
Check the cause
Check the connection at X-03A-22 of the UCM
Check the connection at the harness junction X-200-E12/B10
Check the connection at X-086-1-2 of solenoid Y-002 (the reverse valve)
Check the wiring continuity between X-022B-3 and X-02B-13
Check the wiring continuity between X-022B-6 and X-04A-22
Repair steps
Inspect Wiring
Perform the diagnostic continuity checks listed above using a multimeter. Look for broken wires, corroded pins, or disconnected harness plugs at the specified X-connectors.
Repair Harness/Solenoid
If an open circuit is found in the wiring or the Y-002 solenoid coil is internally open, repair the wire or replace the reverse solenoid valve.
Module Replacement
If all wiring and solenoid connections are intact and the fault is still present, replace the UCM.