3030-13 - DEC

Case IH 3030-13 - DEC – DEC: Hydro static unit control solenoid out of calibration

Issue description

The proportional solenoid responsible for controlling the hydrostatic drive unit has lost its calibration parameters, meaning the controller can no longer accurately determine the solenoid's position or electrical baseline to command the hydrostatic pump/motor effectively.

Applies to these machines

  • MAGNUM AFS Connect
  • Optum series

Check the cause

  1. Check the solenoid's wiring harness for resistance and continuity

Repair steps

  1. Perform forced calibration

    Connect the Case IH Electronic Service Tool (EST) laptop to perform a forced calibration routine on the affected hydrostatic unit control solenoid.

  2. Inspect wiring harness

    If the calibration fails, check the solenoid's wiring harness for resistance and continuity to ensure there are no breaks or shorts.

  3. Replace solenoid

    If the wiring harness is in good condition but the calibration still fails, replace the hydrostatic unit control solenoid.

Parts you might need

(1)
  • Hydrostatic Unit Control Solenoid / Proportional Valve Solenoid

    Generic part name; no specific OEM part number verified in catalogs.

Get help to fix this fault by requesting a quote