Case IH 3107 – Engine Controller: Engine Controller High Pressure Pump Metering Unit Circuit - Short Circuit To Battery
Issue description
The electrical circuit controlling the high-pressure fuel pump's metering unit (Fuel Control Actuator, FCA, or M-Prop) has shorted to a 12V battery power source. This can be caused by a wiring harness short to an external power source, an internal short inside the metering unit itself, or an internal short inside the relay that supplies power to the unit.
Applies to these machines
8 machines- Farmall
- skid steer
- Steiger T4B
- Magnum Series 235 - 340 (Series 4)
- Steiger Series 350 - 600
- Skid Steer Loaders (SSL)
- Compact Track Loaders (CTL)
- 580 Super N Backhoes
Check the cause
Inspect the wiring harness between the Engine Controller, the High Pressure Pump Metering Unit, and the power supply relay for chafed, melted, or pinched wires contacting a 12V battery source.
Test Main Relay 1 (which provides power to the high-pressure pump fuel metering unit) for an internal short to the battery.
Disconnect the metering unit on the high-pressure fuel pump and test the component's pins for an internal short circuit.
Check the Engine Controller (ECU) pins to ensure they are not bent, corroded, or bridged by moisture or debris.
Repair steps
Disconnect Power
Disconnect the machine's battery to prevent further electrical damage during the repair.
Repair Wiring
If the diagnostic checks revealed a short in the wiring harness to an external power source, repair or replace the damaged section of the harness.
Replace the Relay
If Main Relay 1 is internally shorted, replace the relay with a new OEM unit.
Replace the Metering Unit
If the wiring and relay are intact but the metering unit is shorted, remove the defective metering unit from the high-pressure fuel pump and install a new one. Torque the mounting bolts to OEM specifications (e.g., 8.0 N·m / 5.9 lb ft on NEF engines) and reconnect the electrical harness.
Clear Codes and Test
Reconnect the battery. Use the Electronic Service Tool (EST) to clear the fault codes. Run the engine and verify that the rail pressure is within specification and that code 3107 does not return.
Parts you might need
(11)High Pressure Pump Metering Unit
42541851Case IH OEM
High Pressure Pump Metering Unit
84385110Case IH OEM
High Pressure Pump Metering Unit
3947541Case IH OEM
High Pressure Pump Metering Unit
0928400481Bosch OEM
High Pressure Pump Metering Unit
0928400666Bosch OEM
High Pressure Pump Metering Unit
0928400638Bosch OEM
High Pressure Pump Metering Unit
4937597Cummins Cross-Reference
High Pressure Pump Metering Unit
3964009Cummins Cross-Reference
High Pressure Pump Metering Unit
4902916Cummins Cross-Reference
Main Relay 1 (High Pressure Pump Relay)
12V Automotive Relay (Specific part number depends on the chassis fuse box layout).
Engine Controller (ECU)
Only requires replacement if the short circuit permanently burned out the metering driver inside the ECU and the code persists after wiring/component repair.
Get help to fix this fault by requesting a quote