Case IH 3226 – Engine Control Unit (ECU) / EDC (Electronic Diesel Control): CAN timeout error from eVGT Actuator
Issue description
The control module has lost Controller Area Network (CAN) communication with the Electronic Variable Geometry Turbocharger (eVGT) actuator. The system is reporting a timeout error because the CAN-Receive-Frame (SRA2EDC) from the eVGT actuator is disconnected, broken, or missing.
Applies to these machines
7 machines- Steiger T4B
- 240 Series Axial-Flow Combines (7240, 8240, 9240)
- Magnum series (250, 280, 310, 340, 370, 380)
- Steiger series (350)
- Optum series
- Puma series
- Titan series (3530)
Check the cause
Check the voltage supply to the eVGT actuator and verify that the dedicated fuse (often a 20A mini fuse, e.g., F-203) is not blown
Inspect the wiring harness and connectors between the eVGT actuator and the ECU for disconnected plugs, broken wires, or short circuits
Test the CAN High and CAN Low lines at the actuator connector for continuity, short circuits to ground, or short circuits to voltage
Check if the actuator is physically overheated, which can increase internal resistance and cause communication dropouts
Use the Electronic Service Tool (EST) to verify if the fault is active and check for related codes (such as 3864 for internal electrical failure or 3861 for voltage failure)
Repair steps
Safety First
Turn off the engine, remove the key, and disconnect the battery to prevent electrical shorts.
Inspect and Replace Fuses
Locate the machine's fuse box and check the eVGT actuator fuse. Replace it if blown. If it blows again immediately, there is a short to ground in the harness or actuator.
Harness Repair
If diagnostic checks reveal a broken wire or short in the CAN lines or power supply, repair the wiring harness. On some models, there is a specific eVGT adapter harness that can be replaced if damaged.
Replace the Actuator
If the wiring, power, and ground are all verified as good, the CAN controller inside the eVGT actuator has likely suffered an internal failure. Remove the defective eVGT actuator from the turbocharger assembly and install a new one. (Note: Depending on the specific FPT engine model, the actuator may require recalibration using the EST after installation, or the entire turbocharger assembly may need to be replaced if the actuator is not serviced separately).
Reassembly and Testing
Reconnect the battery, clear the fault codes using the EST, and run the engine under load to ensure the code does not return and the turbocharger operates correctly.
Parts you might need
(4)Electronic Variable Geometry Turbocharger Actuator
OEM part numbers vary heavily by specific engine displacement and serial number; often serviced as part of the complete turbocharger assembly
EVGT Adaptor Harness
84558996Fitment: Case IH Titan Floaters and various tractors
Fuse (20A, Mini, Yellow)
84127704Fitment: eVGT actuator power supply on Optum and other models
Fuse (20A, Mini, Yellow)
10401190Fitment: eVGT actuator power supply on Optum and other models
Get help to fix this fault by requesting a quote