Case IH 3258 (DTC 6722) - ECU – Electronic Control Unit (ECU) A-095: Starter relay high side driver circuit short to battery failure
Issue description
The Electronic Control Unit (ECU) A-095 provides voltage to the starter control relay (K-062), which controls voltage to the main starter relay (K-005). The ECU actively monitors the K-062 control circuit and logs this fault if it detects that the high side of the K-062 control circuit is shorted to a battery voltage source.
Applies to these machines
3 machines- MAXXUM T4E
- 240 Series Axial-Flow Combines (7240, 8240, 9240)
- Puma Series Tractors
Check the cause
Verify if an external power supply (such as a jump box or booster battery) is currently connected, as this can artificially trigger the short-to-battery logic
Use the Case IH Electronic Service Tool (EST) to check if the fault is currently active or an inactive/intermittent historical code
Test the machine's charging system for overvoltage conditions
Inspect the wiring harness between the ECU A-095 and the K-062 starter control relay for chafing, melted insulation, or wires shorting to a 12V power source
Test the K-062 control relay, K-005 starter relay, and the starter solenoid for internal shorts
Repair steps
Verify the Code
Connect the EST to the diagnostic port. If the fault is inactive, clear the code and operate the machine to see if it returns. If active, proceed to step 2.
Isolate the Circuit
Disconnect the K-062 starter control relay. Use a multimeter to measure the voltage on the high-side control wire coming from the ECU A-095. If battery voltage is present when the circuit should be unpowered, there is a short to battery in the harness.
Repair Wiring
If a short is found in the harness, locate the damaged section of the wire and repair or replace the harness.
Test the Relay
If the wiring is intact, test the K-062 relay coil. An internally shorted relay can cause feedback to the ECU. Replace the relay if it fails resistance testing.
Software/ECU Replacement
If the wiring and relays are perfectly fine, the fault is likely internal to the ECU A-095. The service manual recommends first attempting to reinstall or flash the ECU A-095 software. If the software flash fails or the code persists, the ECU A-095 must be replaced.
Parts you might need
(7)Starter Relay (K-005 / General)
84543666Relay 12V, 40A, Mini
Starter Relay (K-005 / General)
87696396Relay 12V, 35A, Micro
Starter Relay (K-005 / General)
8201287270-Amp, 4-Pin, 12-Volt Heavy Duty Starter Relay
Starter Relay (K-005 / General)
8398994770-Amp, 4-Pin, 12-Volt Heavy Duty Starter Relay
Starter Relay (K-005 / General)
8752247670-Amp, 4-Pin, 12-Volt Heavy Duty Starter Relay
Starter Control Relay (K-062)
Standard 12V micro/mini control relay; often shares the same part number as K-005
Electronic Control Unit (ECU A-095)
Part numbers are highly specific to the machine's VIN, configuration, and software flash. Must be sourced directly through a Case IH dealer.
Get help to fix this fault by requesting a quote