3259

Case IH 3259 – Engine Control Module: High Side Power _Short circuit to Ground

Issue description

The engine controller has detected that the wiring to the starter relay (or the relay itself) is shorted to ground on the high-side power circuit.

Applies to these machines

  • Case IH Magnum 235 - 340 (Series 4)
  • Case IH Steiger tractors
  • Case 580 Super N
  • Machines utilizing the F5C engine system

Check the cause

  1. Inspect the wiring harness between the Engine Control Module and the starter relay/main power relay for any broken, disconnected, or chafed wires that could cause a short to ground.

  2. Test the starter relay itself to determine if there is an internal short circuit.

Repair steps

  1. Locate relay

    Locate the starter relay / high-side power relay for the engine controller.

  2. Test wiring harness

    Disconnect the relay and use a multimeter to check the wiring harness for continuity to ground on the high-side power circuit.

  3. Repair wiring

    If the wiring is damaged, repair or replace the affected section of the wiring harness.

  4. Replace relay

    If the wiring tests fine, the short is likely inside the relay. Replace the defective relay with a new OEM unit.

  5. Clear fault codes

    Clear the fault codes from the ECM and verify that the code does not return upon startup.

Parts you might need

(5)
  • Starter Relay

    87522476

    Fits various Case IH models including MX100, MX110, MX135, 5088, 5130, 6088, 6130, 7088, 7130, and Cotton Express Pickers

  • Starter Relay

    83989947 / 1987452C1 / 82012872

    Fits Case IH CX series, JX series, MX series, and various New Holland models

  • Starter Relay

    AS162542AP

    70-Amp, 4-Pin, 12-Volt

  • Starter Relay

    700788A1

    35-Amp Starter Relay (Fits Case IH C / CX series and McCormick)

  • Case IH Starter Relay

    87392809

Get help to fix this fault by requesting a quote

Browse other Case IH codes