Case IH 3259 – Engine Control Module: High Side Power _Short circuit to Ground
Issue description
The engine controller has detected that the wiring to the starter relay (or the relay itself) is shorted to ground on the high-side power circuit.
Applies to these machines
4 machines- Case IH Magnum 235 - 340 (Series 4)
- Case IH Steiger tractors
- Case 580 Super N
- Machines utilizing the F5C engine system
Check the cause
Inspect the wiring harness between the Engine Control Module and the starter relay/main power relay for any broken, disconnected, or chafed wires that could cause a short to ground.
Test the starter relay itself to determine if there is an internal short circuit.
Repair steps
Locate relay
Locate the starter relay / high-side power relay for the engine controller.
Test wiring harness
Disconnect the relay and use a multimeter to check the wiring harness for continuity to ground on the high-side power circuit.
Repair wiring
If the wiring is damaged, repair or replace the affected section of the wiring harness.
Replace relay
If the wiring tests fine, the short is likely inside the relay. Replace the defective relay with a new OEM unit.
Clear fault codes
Clear the fault codes from the ECM and verify that the code does not return upon startup.
Parts you might need
(5)Starter Relay
87522476Fits various Case IH models including MX100, MX110, MX135, 5088, 5130, 6088, 6130, 7088, 7130, and Cotton Express Pickers
Starter Relay
83989947 / 1987452C1 / 82012872Fits Case IH CX series, JX series, MX series, and various New Holland models
Starter Relay
AS162542AP70-Amp, 4-Pin, 12-Volt
Starter Relay
700788A135-Amp Starter Relay (Fits Case IH C / CX series and McCormick)
Case IH Starter Relay
87392809
Get help to fix this fault by requesting a quote