Skip to main content
3564

Case IH 3564 – ECU: Plausibility Error of NOx Sensor Values

Issue description

The engine's control module has detected that the readings from the Nitrogen Oxide (NOx) sensor(s) are inconsistent, illogical, or outside of the expected range when compared with other related engine parameters. This plausibility error suggests that the sensor's output is not believable under the current engine operating conditions, which can compromise the monitoring and functionality of the Selective Catalytic Reduction (SCR) system.

Applies to these machines

  • N-Series Tractor Loaders
  • Steiger 470
  • Steiger 500
  • Steiger 540
  • Steiger 580
  • Steiger 620
  • Quadtrac Series Tractors
  • Axial-Flow 7240
  • Axial-Flow 8240
  • Axial-Flow 9240
  • Axial-Flow 7250
  • Axial-Flow 8250
  • Axial-Flow 9250
  • SV340

Check the cause

  1. Read fault codes using a diagnostic tool to confirm code 3564 is active and check for related SCR, DEF quality, or other sensor codes.

  2. Inspect the NOx sensor wiring harness and connectors for damage, such as melting near hot exhaust components, corrosion, or loose pins.

  3. Check power and ground to verify that the suspect NOx sensor is receiving the correct voltage and has a solid ground connection.

  4. Analyze live sensor data from both upstream (pre-SCR) and downstream (post-SCR) NOx sensors at idle and under load. The downstream sensor should show significantly lower NOx values.

  5. Verify DEF system integrity, ensuring DEF concentration is within the correct range (typically 32.5% urea) and checking for dosing issues.

  6. Inspect the exhaust system for any leaks between the upstream and downstream NOx sensors, as air leaks can introduce oxygen and skew readings.

Repair steps

  1. Isolate the faulty sensor

    Based on the diagnostic checks and live data, determine if the fault lies with the upstream or downstream NOx sensor.

  2. Address wiring or connector issues

    If any damage was found during the inspection, repair or replace the affected section of the wiring harness or connector. Clear the fault codes and re-test.

  3. Replace the NOx sensor

    If the sensor itself is determined to be faulty, replace it using the correct OEM part number for the specific machine model and sensor location (upstream or downstream).

  4. Clear fault codes

    After replacement, use a diagnostic tool to clear all related fault codes from the ECU.

  5. Perform system test

    Operate the machine under load to allow the ECU to verify the new sensor's performance and ensure the SCR system is functioning correctly without the code returning.

Parts you might need

(7)
  • NOx Sensor84414466

    General NOx sensor for Case IH Tier 4B equipment

  • NOx Sensor48011210

    General NOx sensor for Case IH Tier 4B equipment

  • Supersedes/interchanges with 47683935 and 48020822

  • NOx Sensor (Before DOC Muffler, 415mm cable)

    Specific part number not fully listed; remanufactured and core options are available

  • NOx Sensor (After SCR Muffler, 615mm cable)

    Specific part number not fully listed; remanufactured and core options are available

  • Downstream NOx Sensor Connector (5 Cavities)

    84190317

    Harness component

  • Blank-off Plug for Connector

    87709655

    Harness component

Get help to fix this fault by requesting a quote

Browse other Case IH codes