Case IH 3674 – Engine Controller / ECU / EDC: EGR Valve Circuit - Under Voltage Error For H-Bridge

Issue description

The H-bridge circuit responsible for controlling the Exhaust Gas Recirculation (EGR) valve is experiencing an under-voltage condition. This error is triggered by high voltage fluctuations within the vehicle's electrical system.

Applies to these machines

  • Farmall
  • skid steer
  • Skid Steer Loaders (SSL)
  • Compact Track Loaders (CTL)
  • backhoe loaders
  • tractor models

Check the cause

  1. Test the vehicle's electrical system for high voltage fluctuations

  2. Check the condition and charge of the batteries

  3. Inspect the alternator for proper voltage output and stability

  4. Examine wiring harnesses and ground connections for damage, corrosion, or loose fittings

Repair steps

  1. Inspect the Electrical System

    Check the vehicle's electrical system (batteries, alternator, wiring harnesses, and grounds) to identify and repair the source of the high voltage fluctuations.

  2. Replace the ECU

    If the electrical system is verified to be stable but the fault persists, the Engine Controller (ECU) has likely been damaged by the voltage fluctuations and must be replaced.

  3. Restore Parameters

    After replacing the Engine Controller (EDC), you must use the appropriate Case IH electronic service tool to restore the engine's self-learning parameters.

Parts you might need

(1)
  • Engine Controller / Engine Control Unit (ECU) / Electronic Diesel Control (EDC)

    5801455298

    Manufactured by Bosch (commonly EDC17C49 or EDC7UC31). Always verify the exact part number against the machine's serial number in the Case IH parts catalog before ordering.