3984

Case IH 3984 – Engine Control Unit (ECU) / Dosing Control Unit (DCU): SCR dosing, time to closed loop too long

Issue description

The system takes too long to enter closed-loop dosing mode. This typically occurs because the exhaust temperature is not reaching the required threshold fast enough, the NOx sensors are failing to reach their operating temperature (dew point), or there is a mechanical issue with the DEF dosing module (pump/valve) preventing it from building pressure and injecting fluid.

Applies to these machines

  • Maxxum
  • Puma
  • Magnum
  • Steiger
  • Farmlift
  • T6
  • T7
  • W110 D
  • W130 D
  • W170 D

Check the cause

  1. Check DEF/AdBlue quality and level to ensure the tank is full and the fluid concentration is correct at approximately 32.5 percent urea.

  2. Check for accompanying fault codes related to NOx sensors (e.g., 3521, 3528, 3529, 3530), exhaust temperature sensors, or DEF pressure, as these will prevent the system from entering closed-loop mode.

  3. Monitor exhaust temperatures upstream and downstream of the SCR catalyst to verify they are reaching the required operating temperatures for dosing.

  4. Verify NOx sensor operation to check if the upstream and downstream sensors are reaching their dew point and providing plausible concentration readings.

  5. Inspect the DEF dosing system by checking the pump for proper pressure build-up and the dosing valve for blockages or crystallization.

  6. Check for exhaust leaks in the piping before the SCR catalyst that could cause a loss of heat or pressure.

Repair steps

  1. Connect Diagnostic Tool

    Connect the CNH Electronic Service Tool (EST) to the machine's diagnostic port to read all active and logged fault codes.

  2. Perform System Tests

    Use the EST to perform a DEF dosing system leak test and a pressure test to verify the dosing valve and supply module (pump) are functioning correctly.

  3. Run a Forced SCR System Test

    Initiate a forced SCR system test or regeneration to monitor exhaust temperatures and NOx sensor readings in real-time.

  4. Replace Faulty Components

    If a NOx sensor is slow to respond, fails to reach its dew point, or shows an open/short circuit, replace the affected NOx sensor. If the DEF dosing valve is blocked and cannot be cleaned of crystallized urea, replace the dosing valve.

  5. Clear Codes and Validate

    Clear the fault codes. To validate the repair, the machine must be operated under load (e.g., minimum 50% load for approximately 20 minutes) to ensure the exhaust reaches the necessary temperature and the system successfully enters closed-loop dosing.

Parts you might need

(9)
  • NOx Sensor (Upstream/Downstream)

    84414466

    Manufactured by Continental / Vitesco Technologies (e.g., 5WK96711A, 5WK96710A, 5WK96779A, 5WK97262). Direct replacement for the factory-fitted SCR system sensors.

  • NOx Sensor (Upstream/Downstream)

    84292579

    Manufactured by Continental / Vitesco Technologies (e.g., 5WK96711A, 5WK96710A, 5WK96779A, 5WK97262). Direct replacement for the factory-fitted SCR system sensors.

  • NOx Sensor (Upstream/Downstream)

    84422745

    Manufactured by Continental / Vitesco Technologies (e.g., 5WK96711A, 5WK96710A, 5WK96779A, 5WK97262). Direct replacement for the factory-fitted SCR system sensors.

  • NOx Sensor (Upstream/Downstream)

    84422747

    Manufactured by Continental / Vitesco Technologies (e.g., 5WK96711A, 5WK96710A, 5WK96779A, 5WK97262). Direct replacement for the factory-fitted SCR system sensors.

  • NOx Sensor (Upstream/Downstream)

    84422750

    Manufactured by Continental / Vitesco Technologies (e.g., 5WK96711A, 5WK96710A, 5WK96779A, 5WK97262). Direct replacement for the factory-fitted SCR system sensors.

  • NOx Sensor (Upstream/Downstream)

    47688088

    Manufactured by Continental / Vitesco Technologies (e.g., 5WK96711A, 5WK96710A, 5WK96779A, 5WK97262). Direct replacement for the factory-fitted SCR system sensors.

  • DEF Dosing Valve / Injector

    Generic part name (often manufactured by Bosch; specific OEM part number depends on the exact engine model).

  • DEF Supply Module / Pump

    Generic part name.

  • Exhaust Temperature Sensors

    Generic part name.

Get help to fix this fault by requesting a quote

Browse other Case IH codes