Case IH 4110 – ATC (Armrest Tractor Controller) or EHR (Electronic Hitch/Remote): Rear Remote No.1 - Output Stage Faulty
Issue description
This code indicates an electrical failure in the output circuit that drives the proportional solenoid/actuator for the first rear remote hydraulic valve. Technically, this means the controller detects an open circuit, a short to ground, a short to power, or an internal hardware failure within the remote valve's electronic actuator head.
Applies to these machines
10 machines- Magnum
- Maxxum
- Steiger T4B
- MAXXUM T4E
- VESTRUM CVX
- Magnum 235
- Magnum 260
- Magnum 290
- Magnum 315
- Magnum 340
Check the cause
Inspect the wiring harness and the electrical connector at Rear Remote Valve No. 1 for dirt, corrosion, moisture, or pushed-back pins.
Use a multimeter to check the wiring between the EHR/ATC module and the remote valve for continuity, shorts to ground, and shorts to 12V power.
Perform a component isolation (swap test) by swapping the electrical connector from Rear Remote No. 1 with the connector for Rear Remote No. 2. If the fault code changes to the corresponding code for the second remote (e.g., 4114 or 4116), the electronic actuator on Valve No. 1 has failed internally. If the fault code remains 4110, the issue is in the tractor's wiring harness or the ATC/EHR controller itself.
Repair steps
Depressurize the System
Turn off the tractor, lower all implements to the ground, and cycle the remote levers/switches to relieve any trapped hydraulic pressure.
Disconnect Power
Disconnect the tractor's battery to prevent electrical shorts during the repair.
Clean the Area
Thoroughly clean the rear remote valve stack with brake cleaner or a pressure washer to prevent dirt from entering the hydraulic system when the valve is removed.
Disconnect Wiring
Unplug the electrical harness from the Rear Remote No. 1 actuator.
Remove the Valve
Unbolt the tie-rods or mounting bolts holding the remote valve assembly in the stack. Carefully separate the faulty valve from the stack.
Install the New Valve
Install the replacement remote valve assembly. Crucial step: Always use new O-rings (e.g., 15.30 mm ID x 2.40 mm) between the valve slices to prevent internal and external leaks. Torque the stack bolts to OEM specifications.
Reassemble
Reconnect the electrical harness and the battery.
Calibration
Start the tractor and use the cab display (Pro 700 / IntelliView) or a dealer diagnostic tool to perform the remote valve calibration procedure. The system must learn the neutral, extend, and retract positions of the new spool.
Test
Connect a hydraulic implement or flow meter to Remote No. 1 to verify proper operation and check for leaks.
Parts you might need
(5)Proportional Hydraulic Valve Actuator / Rear Remote Hydraulic Control Valve Assembly
87384974RRemanufactured Hydraulic Valve Assembly - common on Magnum series
Remote Hydraulic Valve Assembly
186761A5Remote Hydraulic Valve Assembly
186761A3Complete Remote Valve Kit
718366030Complete Remote Valve Kit - used when adding or replacing a full slice
O-Ring
1443798515.30 mm ID x 2.40 mm Thick
Get help to fix this fault by requesting a quote