4119

Case IH 4119 – EHR (Electro-Hydraulic Remote) Controller / Central Controller: Rear remote no. 2 - over voltage

Issue description

This fault code indicates that the voltage detected at the Electro-Hydraulic Remote (EHR) valve for rear remote #2 has exceeded the maximum allowable threshold. This can be caused by an external power surge, a malfunctioning alternator, a wiring short to power, or an internal failure within the EHR valve's own circuitry.

Applies to these machines

  • Magnum
  • Maxxum
  • Steiger T4B
  • MAXXUM T4E
  • VESTRUM CVX
  • Magnum Series (235-340 Series 4, MX210, MX215, MX230, MX245, MX255, MX275)
  • Puma Series (125, 140, 165, 180, 195, 210, 225 CVX)
  • Maxxum Series (100, 110, 115, 120, 125, 130, 140, MXM series)
  • Steiger Series
  • Farmall Series (115U)

Check the cause

  1. Check for external power sources connected to the battery (e.g., high-voltage jump starter or unregulated battery charger) and disconnect immediately.

  2. Test the tractor's alternator output to ensure the voltage regulator is not causing system-wide over-voltage.

  3. Inspect the CAN BUS wiring and 12V supply harness between the rear remote valves and the central controller for rubbed wires causing a short-to-power (specifically check +12V IGN and CAN HIGH/LOW pins).

  4. If charging system and wiring are normal, isolate the #2 EHR valve to confirm internal circuitry failure.

Repair steps

  1. Resolve Power Issues

    Rectify any alternator overcharging issues or remove external power supplies.

  2. Clear the Code

    Use the Electronic Service Tool (EST) or the tractor's on-board diagnostic H-menu to clear the error code.

  3. Test Operation

    Cycle the tractor key and test the #2 remote for normal operation.

  4. Replace the Valve

    If the code immediately returns and wiring is confirmed good, the EHR valve must be replaced. Depressurize the hydraulic system, disconnect the electrical harness, and unbolt the #2 valve slice from the rear remote stack. Install the new valve and torque to spec.

  5. Calibrate / Renumber

    Perform the EHR valve renumbering procedure so the central controller recognizes the new valve on the CAN BUS. This is done either via the EST laptop or by entering the H-Menu (Mode HL) on the instrument cluster and using the remote timer switches to assign the valve to position #2.

Parts you might need

(5)
  • Electro-Hydraulic Remote (EHR) Valve / Remote Control Valve Slice

    Generic part name. Ensure you are purchasing an electronic (EHR) valve slice, not a mechanical remote valve.

  • Remanufactured Hydraulic Valve

    87384974R

    Common on Magnum MX series

  • Rexroth Hydraulic Remote Valve

    87328572

    Common on Maxxum series

  • Remote Hydraulic Valve

    1980448C9

    Common on older 5000 series Maxxums

  • Remote Hydraulic Valve

    1980448C8

    Common on older 5000 series Maxxums

Get help to fix this fault by requesting a quote