Case IH 4147 – EHR (Electro-Hydraulic Remote) control module: Rear Remote No. 4 - Over Voltage
Issue description
The voltage signal returning from the #4 rear remote spool valve actuator or its control circuit is exceeding the maximum expected threshold (typically indicating a short to power or a failed internal potentiometer).
Applies to these machines
9 machines- Magnum
- Maxxum
- Steiger T4B
- MAXXUM T4E
- Magnum Series
- Steiger / Quadtrac Series
- Puma Series
- Maxxum Series
- Optum Series
Check the cause
Harness Inspection: Inspect the EHR control valve wiring harness at the rear of the tractor, specifically tracing the pigtail going to the #4 remote valve. Look for pinched wires, rubbed insulation, or melted loom that could cause a short to battery voltage.
Connector Check: Disconnect the electrical plug at the #4 remote valve. Check for water intrusion, bent pins, or corrosion, which can bridge the 12V power supply to the 5V signal return.
Voltage Testing: With the key ON (engine off), use a multimeter to probe the harness connector for the #4 valve. Verify that the reference voltage is correct (usually 5V) and that the signal wire is not showing battery voltage (12V+) when disconnected.
Swap Test: To isolate whether the issue is in the tractor's wiring/armrest or the valve itself, swap the electrical connector from Remote #3 to Remote #4. If the fault code changes to the #3 remote (e.g., code 4136/4137), the electronic actuator head on the #4 valve is faulty. If the code remains 4147, the issue is in the wiring harness or the armrest controller.
Repair steps
Depressurize and Power Down
Lower all implements to the ground, turn off the engine, and cycle the remote levers in the cab to relieve any residual hydraulic pressure. Disconnect the battery to protect the EHR module.
Access the Valve Stack
Locate the rear remote valve stack at the back of the tractor. Identify valve #4 (usually counted from left to right or bottom to top, depending on the specific chassis).
Repair Wiring (If Applicable)
If the diagnostic checks revealed a short in the harness, splice and heat-shrink the damaged wires, or replace the EHR control valve wire harness entirely.
Replace the Valve Actuator/Spool
If the valve's internal potentiometer or driver is shorted: Disconnect the electrical connector to the #4 valve. Remove the mounting bolts securing the electronic control head (or the entire spool valve slice, depending on if the actuator is serviced separately on your specific model). Install the new valve slice or actuator head. Ensure O-rings are properly seated and lubricated with clean hydraulic oil. Torque the tie-bolts to the manufacturer's specification to prevent spool binding or leaks.
Reassemble and Calibrate
Reconnect the battery and electrical harness. Start the tractor and warm up the hydraulic oil. You must perform an EHR remote valve calibration using the AFS Pro700 display or the dealer electronic service tool so the controller can learn the new valve's neutral and maximum deflection voltages.
Parts you might need
(9)EHR Control Valve Wire Harness (4-Spool)
84158327Common on Magnums/Pumas
EHR Control Valve Wire Harness (4-Spool)
84151662Steiger series
Rear Remote Valve Assembly (Complete Slice)
47829237Double remote assembly
Rear Remote Valve Assembly (Complete Slice)
719195010Rear Remote Valve Assembly (Complete Slice)
87546169CNH generic EHR spool valve
Remote Valve Main Spool (Internal)
47429154Updated spool often used to fix erratic flow/surging issues on these specific EHR valves
EHR Valve Actuator Head
Generic Part Name
Electro-Hydraulic Spool Valve
Generic Part Name
EHR Wiring Harness
Generic Part Name
Get help to fix this fault by requesting a quote