Case IH 4153 – EHR (Electronic Hitch/Hydraulic Remote) controller: Rear remote no. 4 - internal position sensor faulty
Issue description
The control module has detected an electrical fault, out-of-range signal, or failure of the internal position sensor (potentiometer) that monitors the spool position inside the #4 rear hydraulic remote valve.
Applies to these machines
8 machines- Magnum
- Maxxum
- Steiger T4B
- MAXXUM T4E
- Magnum 235-340 (Series 4)
- Steiger / Quadtrac
- Puma
- MX / TG Series
Check the cause
Check for related EHR error codes (such as voltage or CAN communication faults) to rule out broader harness or controller issues
Inspect the 4-pin connector at the #4 rear remote valve pilot head to ensure it is fully seated, undamaged, and pins are tight
Test the circuit between the position sensor connector and the EHR ECU for continuity, short circuits to ground, or open circuits
Isolate the component to confirm if the failure is internal to the spool position potentiometer
Repair steps
Remove the faulty component
Disconnect the electrical connector and unbolt the faulty pilot head (proportional actuator) from the top of the #4 remote valve body.
Install the replacement
Mount the new pilot head valve assembly onto the valve body and reconnect the 4-pin electrical harness.
Reassign valve addresses
Once the new pilot head is installed, you must use the tractor's display/controller to reassign the valve addresses so the EHR controller knows which cab lever controls the newly installed valve head.
Calibrate the valve
Perform the hydraulic valve calibration procedure. This tunes the valve for proper function and flow control.
Clear codes
Clear the 4153 error code from the EHR module and test the #4 remote for normal operation.
Parts you might need
(1)Proportional Actuator / Standard Pilot Head Valve Assembly
47643919Superseded / Replaced Part Numbers: 47434056, 84139664, 84173128, 84478195, 87577686
Get help to fix this fault by requesting a quote