Case IH 4308 – EHR (Electro-Hydraulic Remote): Rear Remote No.6 - Spool Deflection Excessive
Issue description
The internal spool of the #6 rear electro-hydraulic remote valve has traveled beyond its calibrated or physically allowable range.
Applies to these machines
5 machines- Magnum
- Steiger T4B
- Magnum Series
- Steiger Series
- Puma Series
Check the cause
Check for other active EHR error codes. Make a note of them, clear the codes, and test the system for normal operation to see if 4308 returns.
Verify hydraulic pressure with a gauge. Incorrect hydraulic pressure (such as pressure spikes or improper standby pressure) can physically force the spool to over-travel.
Inspect the electrical connections and CAN BUS wiring at the Rear Remote No. 6 valve for corrosion, pushed pins, or harness damage.
Attempt an EHR valve calibration and renumbering procedure using the tractor's electronic service tool or in-cab diagnostic menu to reset the controller's known neutral and end-of-travel limits.
Repair steps
Relieve Pressure
Turn off the tractor, lower all implements, and relieve all hydraulic pressure from the system.
Clear and Retest
Connect a diagnostic tool or use the cab display to clear the 4308 fault code. Operate the #6 rear remote to see if the code immediately returns.
Inspect Connections
Disconnect the wiring harness connecting to the #6 EHR valve. Clean the connector contacts with electrical contact cleaner and ensure they are seated properly.
Calibrate
Run the EHR valve calibration procedure.
Replace the Valve
If calibration fails, the code persists, or the spool is physically sticking, the internal position transducer or the mechanical spool within the #6 EHR valve is faulty.
Removal
Unbolt the faulty #6 EHR valve section from the rear remote valve stack (ensure hydraulic fluid is drained or capped to prevent excessive loss).
Installation
Install the replacement EHR valve section and torque the stack bolts to OEM specifications.
Software Configuration
Reassemble the valve stack, restore hydraulic fluid, and perform the EHR valve renumbering and calibration procedure so the central controller recognizes the new valve.
Parts you might need
(6)Electro-Hydraulic Remote (EHR) Valve Section / Hydraulic Remote Valve Assembly
Generic Part Name
Remanufactured Hydraulic Valve
87384974RRemanufactured Hydraulic Valve (Fits various Case IH Magnum models like MX210, MX255, MX275)
Remote Valve Kit
84173995Fits various Case IH tractors
3rd Remote Valve Kit with Cab
718366030Fits Magnum series
Remote Valve
47699516Fits Case IH Steiger 450, 500, 550, 600
Remote Valve
48149569Fits Case IH Steiger 450, 500, 550, 600
Get help to fix this fault by requesting a quote