Case IH 4320 – EHR (Electronic Hitch/Hydraulic Remote): Rear remote no. 7 - over voltage
Issue description
This code indicates that the control module has detected an abnormally high voltage on the circuit responsible for operating the 7th rear remote hydraulic valve.
Applies to these machines
4 machines- Magnum
- Steiger T4B
- Case IH Magnum 235 - 340 (Series 4)
- Case IH STX Steiger (350 to 600 horsepower models)
Check the cause
Verify that the tractor's battery is not currently connected to an external power supply (such as a high-voltage jump starter or external battery charger).
Test the tractor's alternator and charging system with a multimeter while the engine is running to ensure it is not overcharging the electrical system.
Inspect the wiring harness leading to the #7 rear remote valve for any shorts to power.
If the charging system is outputting the correct voltage and no external power supplies are connected, the fault is isolated to a faulty EHR valve.
Repair steps
Disconnect External Power
If an external power supply or charger is connected to the battery, disconnect it immediately.
Repair Charging System
If the diagnostic tests reveal the alternator is overcharging, repair or replace the alternator and voltage regulator.
Replace the EHR Valve
If the charging system is functioning normally, the internal electronics of the #7 EHR valve have failed. Remove the faulty electrohydraulic remote valve section from the rear hydraulic stack and install a replacement valve.
Clear Codes and Test
Once the cause of the error has been rectified, use an Electronic Service Tool (or perform a battery disconnect reset if supported by the model) to clear the error code. Test the #7 rear remote for normal operation.
Parts you might need
(5)Electrohydraulic Rear Remote Valve (EHR Valve) / Spool Valve Section
Generic Part Name
Remanufactured Hydraulic Valve
87384974RCommon fitment for Magnum series MX210-MX275
EHR Valve / Spool Valve
87546169Common fitment for Maxxum and Puma series
Additional Electrohydraulic Rear Remote Valve Kit
719412074EHR Control Valve Wiring Harness
84151662Common fitment for Steiger 350-620 series, if the harness is found to be shorted
Get help to fix this fault by requesting a quote