Case IH 4331 – EHR (Electro-Hydraulic Remote): Rear Remote No.8 - Checksum Verification Failure
Issue description
The internal memory (EEPROM) on the electronic controller for the 8th rear remote hydraulic valve has failed a data integrity check (checksum). The control module is unable to verify the software or calibration data stored on that specific valve section.
Applies to these machines
4 machines- Magnum
- Steiger T4B
- Case IH Magnum Series 235, 250, 260, 280, 290, 310, 315, 340, 370, 380
- Case IH Steiger / Quadtrac Series 350, 370, 400, 420, 450, 470, 500, 540, 550, 580, 600, 620
Check the cause
Check for any other active EHR error codes that might indicate a broader CAN-BUS communication issue or voltage drop
Document and clear the error code(s) using the Electronic Service Tool (EST) or the tractor's diagnostic display
Cycle the key power and test the rear remote system for normal operation, as checksum errors can sometimes be triggered by a transient voltage spike
Repair steps
Isolate the Valve
Locate the Rear Remote No. 8 valve section on the rear hydraulic stack.
Replace the Valve
Remove the faulty EHR valve section and install a new replacement unit.
Renumber the EHR Valves
Once the new valve is installed, perform the EHR valve renumbering procedure via the tractor's display or EST to configure the central controller to recognize the new valve's CAN address and assign it to the correct in-cab lever.
Calibrate and Test
Clear any remaining fault codes and run a hydraulic calibration/function test to ensure the new remote operates correctly.
Parts you might need
(7)HYD Valve Section
87496186Fits various Magnum 235-380 and Steiger/Quadtrac 350-620 models
Remote Valve
47699516Left Hand configuration
Remote Valve
51421164Left Hand configuration
Remote Valve
48149569Left Hand configuration
Remote Valve
47595558Right Hand configuration
Remote Valve
47434188Right Hand configuration
Remote Valve
87486189Right Hand configuration