Case IH 4356 – Tractor Control Unit (TCU) / Electronic Control Module (ECM): EHR FB 3 Shorted to low source / EHR FB 3 Low Err

Issue description

The sensor feedback voltage drops below 0.25 V on the rear remote control / electro-hydraulic (EHR) system, specifically Remote No. 3. This suggests that the feedback signal is shorted to ground, experiencing an open circuit, or that the potentiometer itself has failed.

Applies to these machines

  • Magnum
  • Steiger T4B
  • Maxxum
  • Puma

Check the cause

  1. Visually inspect the wiring harness running to the third remote valve for any rubbed, pinched, or broken wires that could cause a short to a low source.

  2. Inspect the Tractor Control Unit (TCU) connector (C063) and the implement interface/potentiometer connector (C686).

  3. Ensure the connectors are fully seated, not damaged, the pins are in the correct position, and the fit is tight. Look for loose or corroded wiring.

  4. Inspect the feedback/position sensor (potentiometer) on the third remote circuit for physical faults or damage.

Repair steps

  1. Locate the Component

    Find the third remote valve (EHR valve #3) at the rear of the tractor.

  2. Inspect and Repair Wiring

    Trace the wiring harness from the feedback sensor/potentiometer on remote #3 back to the TCU. Repair any rubbed, pinched, or broken wires.

  3. Service Connectors

    Disconnect the implement interface (potentiometer) connector (C686) and the TCU connector (C063). Clean the pins and ensure a tight fit upon reconnection.

  4. Replace the Sensor

    If the wiring and connectors are intact but the feedback voltage remains below 0.25 V, the potentiometer/sensor on the remote valve is defective. Remove the faulty sensor and install a replacement.

  5. Replace ECM

    If the sensor and wiring are both verified as functional, the ECM itself may be faulty and require replacement.

  6. Clear Codes

    Clear the error DTC code using an Electronic Service Tool or the tractor's diagnostic menu to reset the system and restore 3-point hitch/remote functionality.

Parts you might need

(4)
  • EHR Remote Valve Potentiometer / Position Sensor

    87605245

    Common CNH rotation position sensor for EHR/lifting

  • EHR Remote Valve Potentiometer / Position Sensor

    86977396

    Throttle/Position Potentiometer for CNH tractors and balers

  • EHR Remote Valve Potentiometer / Position Sensor

    87755846

    Case IH EHR Potentiometer

  • Wiring Harness / Connector Pigtail

    Generic repair wire/pigtail (if the harness is found to be rubbed or pinched)

Get help to fix this fault by requesting a quote

Browse other Case IH codes