Case IH 4558 – EHR (Electronic Hitch Regulation) Controller or ATC (Armrest Tractor Controller): Rear EHR control no.3 – not calibrated

Issue description

The Electronic Hitch Regulation (EHR) / Electronic Remote Valve controller has lost the calibration values for the #3 rear remote valve, or the calibration was never successfully completed. The system's computer does not know the exact electrical values for the lever's neutral, full extend, full retract, or float positions. As a failsafe, the tractor will typically lock out the #3 remote valve and display a warning light.

Applies to these machines

  • VESTRUM CVX
  • Case IH Magnum Series (e.g., MX series, 235–340)
  • Case IH Steiger & Quadtrac Series (e.g., 350–600)
  • Case IH Puma Series
  • Case IH Maxxum Series

Check the cause

  1. Check for hard electrical faults (codes 4178 or 4179) which indicate a wiring or hardware failure rather than a calibration loss

  2. Inspect the armrest lever to verify the #3 remote lever physically returns to the center (neutral) position smoothly

  3. Inspect the EHR control valve wire harness at the rear of the tractor for rubbed wires or corrosion at the connectors

Repair steps

  1. Perform an EHR Lever Calibration

    Enter the tractor's diagnostic/calibration menu (often the 'H' menu). Navigate to the EHR / Armrest calibration section. Follow the on-screen prompts to move the #3 lever through its full range of motion (pull fully back, push fully forward, return to neutral). Turn the ignition key to OFF and wait at least 10 to 30 seconds before turning the tractor back on so the controller can save the new calibration values.

  2. Replace the Armrest Potentiometer

    If the tractor refuses to calibrate (e.g., it constantly tells you to 'move EHR to neutral' when the lever is already centered), the potentiometer inside the armrest switch has failed. Open the armrest console and replace the specific SCV lever module.

  3. Replace the Rear Valve Pilot Head

    If the armrest lever calibrates successfully but the remote still locks up under load and throws codes, the electronic pilot head (actuator module) mounted directly on the rear remote valve is likely failing and must be replaced.

Parts you might need

(7)
  • Armrest SCV Lever / Potentiometer Switch

    Generic: EHR Remote Lever Switch / SCV Armrest Control

  • EHR Control Valve Wire Harness

    84151662

    Steiger 4-spool

  • EHR Control Valve Wire Harness

    82032993

    Generic

  • Rear Remote Valve Assembly / Pilot Head

    1980311C6

    For older Magnums

  • Rear Remote Valve Assembly / Pilot Head

    186760A6

    For older Magnums

  • Rear Remote Valve Assembly / Pilot Head

    719412074

    Additional Electrohydraulic Rear Remote Valve

  • Remote Valve Calibration Tool

    CAS2806

    Transducer

Get help to fix this fault by requesting a quote