Case IH 4558 – EHR (Electronic Hitch Regulation) Controller or ATC (Armrest Tractor Controller): Rear EHR control no.3 – not calibrated
Issue description
The Electronic Hitch Regulation (EHR) / Electronic Remote Valve controller has lost the calibration values for the #3 rear remote valve, or the calibration was never successfully completed. The system's computer does not know the exact electrical values for the lever's neutral, full extend, full retract, or float positions. As a failsafe, the tractor will typically lock out the #3 remote valve and display a warning light.
Applies to these machines
5 machines- VESTRUM CVX
- Case IH Magnum Series (e.g., MX series, 235–340)
- Case IH Steiger & Quadtrac Series (e.g., 350–600)
- Case IH Puma Series
- Case IH Maxxum Series
Check the cause
Check for hard electrical faults (codes 4178 or 4179) which indicate a wiring or hardware failure rather than a calibration loss
Inspect the armrest lever to verify the #3 remote lever physically returns to the center (neutral) position smoothly
Inspect the EHR control valve wire harness at the rear of the tractor for rubbed wires or corrosion at the connectors
Repair steps
Perform an EHR Lever Calibration
Enter the tractor's diagnostic/calibration menu (often the 'H' menu). Navigate to the EHR / Armrest calibration section. Follow the on-screen prompts to move the #3 lever through its full range of motion (pull fully back, push fully forward, return to neutral). Turn the ignition key to OFF and wait at least 10 to 30 seconds before turning the tractor back on so the controller can save the new calibration values.
Replace the Armrest Potentiometer
If the tractor refuses to calibrate (e.g., it constantly tells you to 'move EHR to neutral' when the lever is already centered), the potentiometer inside the armrest switch has failed. Open the armrest console and replace the specific SCV lever module.
Replace the Rear Valve Pilot Head
If the armrest lever calibrates successfully but the remote still locks up under load and throws codes, the electronic pilot head (actuator module) mounted directly on the rear remote valve is likely failing and must be replaced.
Parts you might need
(7)Armrest SCV Lever / Potentiometer Switch
Generic: EHR Remote Lever Switch / SCV Armrest Control
EHR Control Valve Wire Harness
84151662Steiger 4-spool
EHR Control Valve Wire Harness
82032993Generic
Rear Remote Valve Assembly / Pilot Head
1980311C6For older Magnums
Rear Remote Valve Assembly / Pilot Head
186760A6For older Magnums
Rear Remote Valve Assembly / Pilot Head
719412074Additional Electrohydraulic Rear Remote Valve
Remote Valve Calibration Tool
CAS2806Transducer
Get help to fix this fault by requesting a quote