Case IH 4560 – EHR (Electronic Hydraulic Remote) control module/valve: Front remote No. 1 - no communications

Issue description

The tractor's main controller has lost CAN bus communication with the Electronic Hydraulic Remote (EHR) valve assigned to the front remote #1 position.

Applies to these machines

  • Puma/Mid Range Magnum
  • MAXXUM T4E
  • VESTRUM CVX
  • Puma series (165, 180, 195, 210, 225, SWB models)
  • Steiger series
  • Magnum series
  • Farmall series
  • Maxxum series

Check the cause

  1. Check for related codes: Look for other active error codes related to the CAN bus system. If multiple EHR valves (e.g., codes 4561, 4562) or other modules are offline, the issue is likely a main CAN bus line failure rather than the specific valve.

  2. Inspect the EHR Diagnostic LED: The EHR 7.5 valves have internal diagnostic LEDs that flash blink codes. It may be necessary to extract the EHR valve from the valve box, next to the connector. The LED is internal and can be seen blinking through the plastic part of the valve wrap, located next to the harness connector. In some cases, you may need to carefully remove paint from the housing next to the connector to see it.

  3. Wiring & Connector Check: Inspect the wiring harness and connector at the Front Remote No. 1 EHR valve for corrosion, bent pins, or physical damage.

  4. Power & Ground: Verify that the valve is receiving proper 12V power and ground.

Repair steps

  1. Disconnect Power

    Turn off the machine and disconnect the battery before servicing the electrical connections.

  2. Clean and Reseat

    Disconnect the harness from the Front Remote No. 1 EHR valve. Clean the contacts with electrical contact cleaner, apply dielectric grease, and securely reconnect it.

  3. Harness Repair

    If the harness is damaged, repair the broken wires or replace the EHR control valve wire harness section.

  4. Replace the Valve

    If the harness, power, ground, and CAN bus continuity are all verified as good, but the valve still does not communicate (or the internal LED indicates a fatal hardware failure), the Front Remote No. 1 EHR valve must be replaced.

  5. Clear Codes

    Reconnect the battery. Use the tractor's diagnostic menu (e.g., the "HC menu" on Puma/Magnum models) to erase all stored error codes.

  6. Test and Calibrate

    Test the hydraulic system for normal operation. Depending on the model, a spool calibration procedure may need to be run for the new valve.

Parts you might need

(12)
  • EHR Control Valve Wire Harness

    51618178
  • EHR Control Valve Wire Harness

    84151662

    Steiger

  • EHR Control Valve Wire Harness

    84158327
  • EHR Control Valve Wire Harness

    82032993
  • EHR Valve / Spool Valve

    87546169
  • EHR Valve / Spool Valve

    84175671
  • EHR Valve / Spool Valve

    47532950
  • EHR Valve / Spool Valve

    47532954
  • EHR Valve / Spool Valve

    47532947
  • EHR Valve / Spool Valve

    5192188
  • EHR Valve / Spool Valve

    84178547
  • Remanufactured Hydraulic EHR Valve

    87384974R

    Common for Magnum series

Get help to fix this fault by requesting a quote

Browse other Case IH codes