517761-04 - UCM

Case IH 517761-04 - UCM – UCM: Electro-hydraulic backup steering pressure sensor voltage low

Issue description

The signal voltage returning from the backup steering pressure sensor has dropped below the minimum acceptable threshold, indicating a potential short to ground, an open circuit, or a failed sensor.

Applies to these machines

  • MAGNUM AFS Connect
  • Magnum 400 AFS Connect

Check the cause

  1. Use the electronic service tool (EST) to confirm the fault code is currently active.

  2. Check the wiring harness and connectors leading to the backup steering pressure sensor for physical damage, corrosion, or backed-out pins.

  3. Measure the sensor supply voltage at the connector to verify the UCM is supplying a 5V reference (between 4.8 V and 5.2 V). A reading outside this range indicates a wiring issue or a UCM fault.

  4. If the reference voltage and ground are good, test the sensor itself as it is likely internally shorted and causing the low voltage reading.

Repair steps

  1. Repair wiring

    Repair any damaged wiring or replace the faulty connector pigtail if a short/open is found.

  2. Replace sensor

    Replace the electro-hydraulic backup steering pressure sensor if it has failed internally.

  3. Clear fault codes

    Reconnect the harness, turn the ignition key ON, and use the electronic maintenance tool to clear the fault codes and verify the machine can return to service.

Parts you might need

(1)
  • Electro-hydraulic backup steering pressure sensor

    Applies to the backup steering hydraulic circuit on Case IH Magnum AFS Connect tractors.