Case IH 517765-02 - ACM – ACM: Worklight memory 1 switch circuit fault
Issue description
Data from the switch circuit is erratic, intermittent, or incorrect.
Applies to these machines
1 machine- MAGNUM AFS Connect
Check the cause
Inspect the physical condition and mechanical action of the Worklight Memory 1 switch located on the configurable armrest.
Check the wiring harness and connectors between the Worklight Memory 1 switch and the Armrest Controller Module (ACM) for loose pins, corrosion, or chafing that could cause intermittent signal drops.
Verify that the ACM is communicating properly on the CAN bus and is not logging secondary voltage or communication errors.
Repair steps
Replace the faulty switch
Replace the Worklight Memory 1 switch if it is found to be faulty.
Repair the armrest harness
Repair the damaged section of the armrest harness if wiring issues are found.
Replace the ACM
In rare cases, replace the Armrest Controller Module (ACM) if the internal circuit board has failed.
Parts you might need
(3)Worklight Memory Switch
Configurable armrest button
Armrest Wiring Harness
Armrest Controller Module (ACM)
Get help to fix this fault by requesting a quote