Case IH 518109-00 - BCM – BCM: Work lamp #12 - too many loads or faulty load
Issue description
The system detects too many loads or a faulty load on the Work lamp #12 circuit, indicating a current draw higher than the safe ampacity level or a short circuit.
Applies to these machines
1 machine- MAGNUM AFS Connect
Check the cause
Visually inspect the Work Lamp #12 circuit to see if any unauthorized aftermarket lights or accessories have been added, which would exceed the circuit's safe load limit.
Use the machine's wiring diagram to test the work lamp wiring harness for shorts to ground or open circuits.
Check the load switch to verify that the load status changes correctly when the switch position is toggled.
Inspect the specific fuses and relays associated with the work lamp control unit.
Repair steps
Disconnect Power
Turn off the machine and disconnect the battery to prevent electrical arcing.
Remove Excess Loads
If multiple appliances or lamps have been wired into the Work Lamp #12 circuit, remove them to bring the current draw back below the circuit's maximum ampacity.
Repair Wiring
If harness testing revealed a short circuit or open wire, repair or replace the damaged section of the wiring harness.
Replace Faulty Components
If the load switch fails the status change test, replace the load switch. If the work lamp itself has an internal short, replace the lamp assembly.
Clear and Retest
Reconnect the battery, clear the fault code from the BCM, and turn on the work lamps to verify the code does not return.
Parts you might need
(5)Work Lamp Assembly
Halogen or LED, depending on OEM fitment
Load Switch / Relay
Wiring Harness / Connectors
e.g., butt connectors, shrink tubing
Fuses
e.g., 10A, 15A, or 20A depending on the specific work lamp circuit rating
Body Control Module (BCM)
Only if the internal circuit driver has been permanently damaged by the overload