518394-05 - VCM

Case IH 518394-05 - VCM – VCM: Trailer brake pedal control solenoid current low

Issue description

The control module is detecting an open circuit, abnormally high resistance, or a disconnected wire in the trailer brake solenoid circuit. Note: An official Case IH document also defines this code as 'Fan speed sensor reading indicates zero speed with engine running'.

Applies to these machines

  • MAGNUM AFS Connect
  • Magnum 400 AFS Connect (Tier 3)
  • Puma (185–260 CVX)
  • Maxxum
  • Optum

Check the cause

  1. Check the wiring harness for open circuits or high resistance between the VCM and the trailer brake pedal control solenoid.

  2. Verify the presence and correct connection of the controller to the network, and check its voltage supply.

  3. Check for a proper ground connection on the power cables.

Repair steps

  1. Inspect wiring and connectors

    Inspect the wiring and connectors leading to the trailer brake pedal control solenoid for open circuits, corrosion, or physical damage.

  2. Check ground and power

    Check the ground connections and power supply to the VCM and the solenoid.

  3. Diagnose internal failure

    If the wiring and grounds are intact, the fault is likely an internal failure of the solenoid valve assembly or the VCM itself.

  4. Replace solenoid/valve

    Replace the faulty trailer brake solenoid/valve if it has failed internally.

  5. Erase fault code and retest

    Erase the fault code from the VCM and retest the trailer brake system to ensure the code does not return.

Parts you might need

(3)
  • Case New Holland Trailer Brake Solenoid

    5177698

    Fitment notes: JX, MAXXUM, MXU, PUMA

  • Trailer Brake Valve

    1533774C2

    Genuine Case IH

  • OEM Brake Solenoid Valve Assembly

    430623A1

    Fitment notes: Case Construction equipment

Get help to fix this fault by requesting a quote