518436-02 - ACM

Case IH 518436-02 - ACM – ACM: Radio display shortcut switch circuit fault

Issue description

The system is detecting an erratic or out-of-range electrical signal on the circuit dedicated to the shortcut switch that controls the radio display.

Applies to these machines

  • MAGNUM AFS Connect

Check the cause

  1. Verify the fault code status (Active vs. Inactive/Stored)

  2. Inspect the physical 'Shortcut Switch' on the armrest console for sticking, physical damage, or liquid intrusion

  3. Check the wiring harness between the shortcut switch cluster and the Armrest Controller Module (ACM) for shorts to ground, shorts to power, or open circuits

  4. Verify the CAN bus communication lines to the ACM

Parts you might need

(3)
  • Armrest Controller Module (ACM)

  • Armrest Switch Cluster / Keypad

  • Radio Display Shortcut Switch

Get help to fix this fault by requesting a quote

Browse other Case IH codes