Case IH 518560-01 - ACM – ACM: Internal failure in EHR lever 2
Issue description
The internal circuitry, potentiometer, or encoder within EHR lever 2 (Lever B) has failed, preventing the module from accurately reading the lever's position command (raise/lower/float).
Applies to these machines
5 machines- MAGNUM AFS Connect
- Magnum AFS Connect series
- Steiger AFS Connect series
- Puma series (Tier 4A / Tier 4B and newer)
- Optum series (Tier 4A / Tier 4B and newer)
Check the cause
Check for Software/Calibration Issues: Attempt to recalibrate the EHR levers using the tractor's display (EIC/Pro 1200). If the lever was recently replaced or the controller updated, it must be calibrated. If calibration fails or the code immediately returns, proceed to hardware checks.
Inspect Wiring: Open the armrest controller housing and inspect the wiring harness and connector to EHR Lever 2. Ensure there are no pinched wires, shorts, or loose connections.
Swap Test: Swap the electrical connection of EHR Lever 2 (Lever B) with an adjacent lever (e.g., EHR Lever 3). If the fault code changes to the corresponding code for Lever 3 (518561-01), the lever itself is confirmed faulty. If the code remains 518560-01, the issue lies within the ACM or the armrest wiring harness.
Repair steps
Disconnect battery power
Turn off the tractor and disconnect battery power to prevent electrical shorts while servicing the ACM.
Open armrest housing
Remove the retaining screws to open the MultiControl Armrest housing/console.
Disconnect wiring harness
Locate the EHR lever block. Disconnect the specific wiring harness connector attached to EHR Lever 2.
Remove mounting hardware
Remove the mounting hardware securing the faulty EHR lever to the armrest assembly.
Install new lever
Remove the old lever and install the new replacement EHR lever.
Reconnect wiring and hardware
Secure the mounting hardware and reconnect the wiring harness.
Reassemble housing
Reassemble the armrest housing.
Restore power
Restore battery power and turn the tractor key to the ON position.
Calibrate EHR lever
Perform the EHR lever calibration procedure via the tractor's display so the ACM can learn the new lever's minimum, maximum, and neutral potentiometer values.
Parts you might need
(6)LEVER; EHR Black
90493683Replaces older # 47995201. Individual lever for raise, lower, extend, retract.
LEVER; EHR Black
47995201Older part number replaced by 90493683.
Electro-Hydraulic Remote Lever - Blue
47995223SET OF LEVERS, EHR
84235842Complete block for 6 Remotes, includes wire harnesses.
SET OF LEVERS, EHR
90493669Complete block for 6 Remotes, includes wire harnesses.
KNOB; EHR Lever
406962A1If only the physical knob is damaged, though an internal failure requires the lever base/potentiometer replacement.