518560-03 - ACM

Case IH 518560-03 - ACM – ACM: EHR lever 2 voltage high

Issue description

The voltage signal returning from the EHR lever's internal potentiometer/encoder to the controller is higher than the permissible range. This typically indicates a short circuit to a power source, a broken ground wire, or an internal failure of the lever's electronic sensor.

Applies to these machines

  • MAGNUM AFS Connect
  • Magnum Series (e.g., Magnum 235-340, Magnum 400 AFS Connect)
  • Steiger / Quadtrac Series (e.g., Steiger 350-600)
  • Puma Series

Check the cause

  1. Inspect the wiring harness and connectors between EHR Lever 2 and the Armrest Control Module (ACM) for pinched wires, corrosion, or a short circuit to a higher voltage source.

  2. Use the tractor's diagnostic display (AFS Pro monitor or EIC) to observe the live voltage readings of EHR Lever 2. Check if the voltage is stuck at a high value regardless of the lever's physical position.

  3. Swap the electrical connector of EHR Lever 2 (Lever B) with an adjacent, functioning lever (such as Lever 1 or 3). If the high voltage fault code follows the lever, the EHR lever itself has failed internally. If the fault code remains on Lever 2, the issue is in the wiring harness or the ACM.

  4. Verify the ACM configuration. Attempt to recalibrate the levers via the display, as a loss of calibration can sometimes cause out-of-range errors.

Repair steps

  1. Power Down

    Turn off the tractor and disconnect the battery to prevent electrical shorts during repair.

  2. Access the Console

    Remove the upper cover assembly/housing of the right-hand armrest console to expose the electronic controls and EHR lever block.

  3. Disconnect

    Locate EHR Lever 2 (Lever B) and carefully unplug its electrical harness connector.

  4. Remove the Lever

    Remove the mounting screws (typically #8-32 x 3/8" slotted pan head or M4 x 20 hex socket head screws) that secure the EHR lever assembly to the mounting plate.

  5. Install the New Part

    Seat the new EHR lever assembly into the mounting plate and secure it with the screws.

  6. Reassemble

    Reconnect the electrical harness to the new lever and reinstall the armrest console cover.

  7. Calibrate

    Reconnect the battery, power on the tractor, and navigate to the configuration screen for the EHR levers on the display. Follow the on-screen prompts to calibrate the new lever's detent and center positions.

Parts you might need

(2)
  • EHR Lever Assembly (Electronic Control Valve Lever)

    90493683

    Replaces older part numbers 47995201 and 87486098. This is the complete electronic lever assembly required to fix internal voltage/sensor failures.

  • EHR Lever Knob (Cosmetic/Physical Grip)

    406962A1

    Replaces 87776204. Only replace this if the physical plastic knob is broken; replacing the knob will not fix a voltage fault.

Get help to fix this fault by requesting a quote

Browse other Case IH codes