518560-14 - ACM

Case IH 518560-14 - ACM – ACM: Incorrect EHR lever 2 configuration

Issue description

The control module has detected that the Electro-Hydraulic Remote (EHR) lever has an incorrect configuration, has lost its calibration data, or is not calibrated properly.

Applies to these machines

  • MAGNUM AFS Connect
  • Steiger/Quadtrac AFS Connect

Check the cause

  1. Check the display for any other active ACM (Armrest Control Module) error codes or communication loss codes (e.g., 4004 or 4005).

  2. Determine if the EHR lever, the armrest controller, or the EHR control unit was recently replaced or flashed. If so, the lever simply needs to be calibrated.

  3. Inspect the electrical connectors beneath the armrest going to the EHR lever block. Ensure the connectors are seated tightly, not damaged, and that the pins are in the correct position.

Repair steps

  1. Clear the code

    Clear the error code from the system memory and test the EHR lever for normal operation.

  2. Calibrate the EHR Lever

    If the fault returns, perform the EHR lever calibration procedure. On Vision Pro/AFS Connect monitors, this is typically done by navigating to the EHR settings screen or the Calibration Wizard (Vehicle Settings > Menu Diagnostics > Vehicle Diagnostics > Calibration Wizard) and following the on-screen prompts to set the lever parameters.

  3. Update Software

    If the EHR lever was calibrated but the error code still occurs, download and flash the correct and most up-to-date level of software to the ACM, then repeat the EHR lever calibration procedure.

  4. Replace the Component

    If the fault occurs again after software updates and a successful calibration attempt, the internal potentiometers/sensors in the EHR lever are faulty. You must remove and replace the EHR control unit / lever block.

Parts you might need

(3)
  • EHR Lever Assembly

    90493683

    Raise, lower, extend. Exact part numbers will vary slightly depending on your tractor's specific spool configuration.

  • EHR Lever Knob

    406962A1

    Replacement knob.

  • Armrest EHR Lever Block / EHR Control Unit

    Generic part name if specific assembly number differs.