518561-06 - ACM

Case IH 518561-06 - ACM – ACM: EHR lever C (or EHR 3) voltage low

Issue description

The Armrest Control Module (ACM) is detecting an abnormally low voltage signal from the Electro-Hydraulic Remote (EHR) lever C (also designated as EHR lever 3). This is typically caused by a short to ground in the wiring harness, a disconnected plug, or a total internal failure of the lever's sensor.

Applies to these machines

  • MAGNUM AFS Connect
  • Magnum Series (235, 245, 260, 290, 340)
  • Steiger Series (500)
  • Puma Series (175, 200, 215, 230)
  • Maxxum Multicontroller Series (110, 120, 130, 140)

Check the cause

  1. Perform a lever swap test: Swap the electrical connector of EHR lever C with an adjacent lever. If the fault code changes to the new lever's position, the lever has failed internally. If the code remains, the issue is in the wiring harness or ACM.

  2. Inspect the wiring harness between the EHR lever block and the ACM for pinched wires under the armrest plastics, chafing, or backed-out pins in the connectors.

  3. Attempt to recalibrate the EHR levers via the tractor's display. If the lever fails calibration immediately due to no signal, the sensor is dead.

Repair steps

  1. Power Down

    Turn off the tractor, remove the key, and turn off the battery disconnect switch to prevent electrical spikes to the ACM.

  2. Access the Armrest

    Remove the retaining screws on the underside or side profile of the right-hand armrest console to lift off the top plastic cover.

  3. Remove the Lever Block

    Disconnect the wiring harness pigtail from the bottom of EHR lever C (Lever 3).

  4. Extract the Lever

    Remove the mounting screws securing the specific EHR lever to the armrest chassis and pull the lever assembly out.

  5. Install the New Part

    Seat the new EHR lever into the console, secure the mounting screws, and plug in the electrical connector.

  6. Reassemble

    Reinstall the armrest covers and turn the battery disconnect back on.

  7. Calibrate

    You must perform the EHR lever calibration procedure using the tractor's display monitor so the ACM can learn the minimum, maximum, and neutral voltage values of the new lever's potentiometer. Failure to calibrate will result in the lever not functioning or throwing immediate out-of-range codes.

Parts you might need

(5)
  • EHR Lever Assembly

    90493683

    Standard EHR Lever replacement for many late-model CNH armrests

  • EHR Lever / Knob Assembly

    406962A1

    Magnum specific

  • Armrest Control Module (ACM) ECU

    48068685

    Only replace if the module itself is proven to be the point of failure after harness testing

  • Armrest Control Module (ACM) ECU (Reman)

    48068685R

    Only replace if the module itself is proven to be the point of failure after harness testing

  • Armrest Control Module (ACM) ECU

    47443335

    Only replace if the module itself is proven to be the point of failure after harness testing

Get help to fix this fault by requesting a quote

Browse other Case IH codes