Case IH 518561-06 - ACM – ACM: EHR lever C (or EHR 3) voltage low
Issue description
The Armrest Control Module (ACM) is detecting an abnormally low voltage signal from the Electro-Hydraulic Remote (EHR) lever C (also designated as EHR lever 3). This is typically caused by a short to ground in the wiring harness, a disconnected plug, or a total internal failure of the lever's sensor.
Applies to these machines
5 machines- MAGNUM AFS Connect
- Magnum Series (235, 245, 260, 290, 340)
- Steiger Series (500)
- Puma Series (175, 200, 215, 230)
- Maxxum Multicontroller Series (110, 120, 130, 140)
Check the cause
Perform a lever swap test: Swap the electrical connector of EHR lever C with an adjacent lever. If the fault code changes to the new lever's position, the lever has failed internally. If the code remains, the issue is in the wiring harness or ACM.
Inspect the wiring harness between the EHR lever block and the ACM for pinched wires under the armrest plastics, chafing, or backed-out pins in the connectors.
Attempt to recalibrate the EHR levers via the tractor's display. If the lever fails calibration immediately due to no signal, the sensor is dead.
Repair steps
Power Down
Turn off the tractor, remove the key, and turn off the battery disconnect switch to prevent electrical spikes to the ACM.
Access the Armrest
Remove the retaining screws on the underside or side profile of the right-hand armrest console to lift off the top plastic cover.
Remove the Lever Block
Disconnect the wiring harness pigtail from the bottom of EHR lever C (Lever 3).
Extract the Lever
Remove the mounting screws securing the specific EHR lever to the armrest chassis and pull the lever assembly out.
Install the New Part
Seat the new EHR lever into the console, secure the mounting screws, and plug in the electrical connector.
Reassemble
Reinstall the armrest covers and turn the battery disconnect back on.
Calibrate
You must perform the EHR lever calibration procedure using the tractor's display monitor so the ACM can learn the minimum, maximum, and neutral voltage values of the new lever's potentiometer. Failure to calibrate will result in the lever not functioning or throwing immediate out-of-range codes.
Parts you might need
(5)EHR Lever Assembly
90493683Standard EHR Lever replacement for many late-model CNH armrests
EHR Lever / Knob Assembly
406962A1Magnum specific
Armrest Control Module (ACM) ECU
48068685Only replace if the module itself is proven to be the point of failure after harness testing
Armrest Control Module (ACM) ECU (Reman)
48068685ROnly replace if the module itself is proven to be the point of failure after harness testing
Armrest Control Module (ACM) ECU
47443335Only replace if the module itself is proven to be the point of failure after harness testing
Get help to fix this fault by requesting a quote