518562-13 - ACM

Case IH 518562-13 - ACM – ACM: EHR lever D sensor disagreement / EHR lever 4 low voltage

Issue description

The fault indicates a sensor disagreement or a low voltage condition on Electro-Hydraulic Remote (EHR) Lever 4 (often designated as Lever D). The system detects that the electrical signal from the lever's position sensor is lower than the expected threshold or out of range, meaning the module cannot accurately determine the physical position of the lever.

Applies to these machines

  • MAGNUM AFS Connect
  • Case IH Magnum Series: AFS Connect Magnum (180, 200, 220, 240, 250, 280, 310, 340, 380, 400)
  • Case IH Steiger Series: 350, 400, 450, 500, 550, 600
  • Case IH Puma Series (equipped with Multicontroller armrest and EHR valves)
  • Case IH Maxxum Series (equipped with Multicontroller armrest and EHR valves)

Check the cause

  1. Check if the EHR lever has lost its calibration via the tractor's display (e.g., AFS Pro 1200 or EIC)

  2. Inspect EHR Lever 4 (D) on the armrest for physical damage, sticking, or debris preventing full travel

  3. Check the voltage supply and signal return for Lever 4 using a multimeter. Look for an open circuit in the 5V reference supply wire, a short to ground in the signal wire, or backed-out pins at the ACM connector

  4. Perform a swap test by exchanging the electrical connection of Lever 4 with an adjacent lever (e.g., Lever 3/C) to determine if the fault follows the lever or stays with the wiring/ACM

Repair steps

  1. Power Down

    Turn off the tractor, apply the parking brake, and disconnect the battery ground to prevent electrical spikes.

  2. Access the Armrest Internals

    Remove the protective covers/screws on the armrest console to expose the EHR lever block and the Armrest Control Module (ACM).

  3. Repair Wiring (If Applicable)

    If your diagnostic checks revealed a broken wire or short to ground, repair the wiring harness and replace any damaged connector pins.

  4. Replace the EHR Lever (If Faulty)

    Disconnect the electrical connector from the bottom of EHR Lever 4. Remove the retaining screws holding the lever assembly in the armrest block. Install the new EHR lever and secure the hardware. Reconnect the electrical harness.

  5. Reassemble and Power Up

    Reinstall the armrest covers and reconnect the battery.

  6. Recalibrate

    You must perform the EHR lever calibration procedure after replacing a lever or the ACM. Navigate to the calibration menu on the display and follow the on-screen prompts to set the neutral, maximum extend, and maximum retract positions.

  7. Clear Codes

    Clear the inactive 518562-13 code from the ACM memory and test the remote valve operation.

Parts you might need

(5)
  • EHR Control Lever (Raise/Lower/Extend)

    90493683

    Standard EHR lever assembly

  • EHR Control Lever (Ginger/Color-Coded)

    87613725
  • EHR Lever Knob

    406962A1

    If replacing just the cap

  • Armrest Control Module (ACM) ECU

    48068685

    Electronic Control Unit for ACM

  • Armrest Control Module (ACM) Assembly

    48068689

    Replaces older part numbers 84356319 and 84206614