Case IH 518563-01 - ACM – ACM: EHR lever E internal failure
Issue description
The system's controller has detected that the electrical signal (voltage) from the lever's internal potentiometer is out of the expected range, implausible, or failing to register the correct detent positions (such as neutral, float, raise, or lower).
Applies to these machines
4 machines- MAGNUM AFS Connect
- Case IH Magnum Series
- Case IH Steiger / Quadtrac Series
- Case IH Maxxum Series
Check the cause
Check Calibration Values: Connect the Electronic Service Tool (EST) or use the tractor's in-cab instrumentation (EHR CAL screen) to view the lever's voltage values. Expected values: Neutral = 550 mV, Float = 0 mV, Lower = 180 mV, Raised = 910 mV. Deviations of 30 mV or higher indicate internal failure.
Clear Debris / Spool Check: Stroke the valve back and forth manually or via the lever to clear any potential debris, then attempt to recalibrate.
Harness Testing: Test the wiring harness from the armrest controls to the ACM to rule out a short or open circuit before condemning the lever itself.
Temporary Workaround: Switch your implement hoses to a different remote valve (e.g., SCV 1 instead of the failed SCV) to confirm the issue is isolated strictly to that specific lever/circuit.
Repair steps
Save Existing Data
Before replacing the lever or updating the ACM, open EST, select "ACM Configuration," and save the previous calibration values from the EHR levers to a file.
Prepare the Tractor
Ensure the tractor is not moving, the parking brake is applied, and the engine is off with the ignition on.
Access the Lever
Remove the armrest console cover to access the EHR lever assembly (often referred to as the pilot head or electric module).
Remove the Faulty Component
Disconnect the wiring harness from the faulty EHR lever E and unbolt it from the armrest bank.
Install the New Lever
Mount the replacement EHR lever and reconnect the wiring harness.
Calibrate the New Lever
The CAN-based EHR valves must be calibrated prior to use. Navigate to the EHR CAL screen on the display (or use EST) and follow the prompts to calibrate the new lever's detent positions.
Clear Codes
Clear the stored fault codes from the ACM and test the remote valve for proper operation.
Parts you might need
(2)Electro-Hydraulic Remote (EHR) Lever - Blue
47995223EHR levers are often color-coded to match the corresponding remote valve on the back of the tractor. Ensure you order the correct color/number for Lever E (which usually corresponds to remote #5).
Control Lever
87613725Alternative OEM Part Number. A "Service KIT REHR" may also be referenced in OEM literature for complete replacements.