Case IH 518565-01 - ACM – ACM: Internal failure in EHR lever 7
Issue description
Indicates an internal failure in EHR lever 7 (which corresponds to EHR lever G). This fault code is logged against the Armrest Control Module (ACM).
Applies to these machines
4 machines- MAGNUM AFS Connect
- Case IH Magnum AFS Connect
- Case IH Steiger AFS Connect
- Case IH Puma AFS Series
Check the cause
Check if the EHR lever was recently calibrated or if a controller/EHR control unit was changed without calibration
Repeat the EHR lever calibration procedure to see if the module can successfully relearn the lever's position
Download the correct level of software to the module and perform the calibration procedure once more
Verify that the wiring harness and connectors between the EHR lever and the Armrest Control Module (ACM) are secure and undamaged
Repair steps
Power down and depressurize
Power down the tractor and ensure the hydraulic system is depressurized.
Access EHR lever assembly
Open the armrest controller housing to access the EHR lever assembly.
Disconnect electrical connector
Disconnect the electrical connector for the affected EHR lever (Lever 7 / G).
Remove faulty lever
Remove the faulty EHR lever from the armrest control panel.
Install replacement lever
Install the replacement EHR lever and reconnect the wiring harness.
Reassemble housing
Reassemble the armrest housing.
Perform calibration
Turn the tractor on and use the Electronic Service Tool (EST) or the tractor's Pro display to perform a mandatory EHR lever calibration procedure for the new lever.
Parts you might need
(3)Electro-Hydraulic Remote (EHR) Lever (Black)
47995201Replaced by / Alternate Part # 90493683
Set of Levers (EHR, 6 Remotes)
84235842Replaced by Part # 90493669 (if applicable to the specific build)
Armrest ACM (Remanufactured ECU)
91807743RIf the internal failure is determined to be on the ACM board itself rather than the lever