Case IH 518566-03 - ACM – ACM: EHR lever H (Lever 8) voltage high / Internal failure
Issue description
The Armrest Control Module (ACM) has detected that the signal voltage from the Electro-Hydraulic Remote (EHR) lever H (also designated as Lever 8 in some translated manuals) is above the normal operating range. This typically indicates a short to power (12V) on the signal circuit, an open ground circuit (which causes the signal to pull high), or an internal failure of the potentiometer/switch inside the lever assembly.
Applies to these machines
17 machines- MAGNUM AFS Connect
- Magnum 235-340
- Magnum 380
- Magnum 400
- Steiger 350
- Steiger 370
- Steiger 400
- Steiger 420
- Steiger 450
- Steiger 470
- Steiger 500
- Steiger 540
- Steiger 550
- Steiger 600
- Steiger 620
- Puma
- Maxxum
Check the cause
Visually inspect EHR lever H on the armrest for physical damage, sticking, or binding.
Verify if the EHR lever is properly calibrated by entering the H-Menu / Armrest Calibration menu (an uncalibrated lever can trigger faults).
With the key switch OFF, disconnect the connectors at both the EHR lever and the ACM, then use a multimeter to measure voltage on the signal wire to check for a short to 12 volts.
Perform a continuity test on the wiring harness between the EHR lever and the ACM to check for open circuits. Ensure the ground circuit is intact, as an open ground will cause the potentiometer voltage to read high.
Repair steps
Power Down
Turn off the key switch and disconnect the battery (or pull the relevant fuse) before servicing electrical components.
Access the Armrest
Remove the necessary trim panels on the MultiControl Armrest to access the EHR lever block.
Disconnect and Isolate
Disconnect the wiring harness from EHR lever H.
Test the Harness
Perform the continuity, short-to-ground, and short-to-power tests outlined above.
Replace the Lever
If the wiring harness tests good, the fault is internal to the EHR lever assembly. Remove the defective EHR lever from the armrest panel and install the new replacement lever.
Reassemble and Power Up
Reconnect the wiring harness, reassemble the armrest, and reconnect the battery.
Calibrate the Lever
You must perform the EHR lever calibration procedure after replacing the lever or the ACM. Turn the key switch to ON, enter the armrest controller calibration main menu (usually within the first 10 seconds of key-on), select the calibration option for the EHR control lever, and follow the display prompts to calibrate the lever's full range of motion.
Clear Codes
Clear the fault codes and test the hydraulic remote operation to confirm the repair.
Parts you might need
(6)Electro-Hydraulic Remote Lever (Blue)
47995223Reman Service EH Lever Control (8-Volt)
47372893REHR Lever Assembly
90493683Set of Levers
842358426 EHR, includes wire harnesses
EHR Lever Knob
406962A1if only the physical knob is damaged
EHR Control Valve Wiring Harness
841516624 Spool, Steiger models
Get help to fix this fault by requesting a quote