Case IH 518566-06 - ACM – ACM: EHR lever H voltage low
Issue description
The signal voltage from the Electro-Hydraulic Remote (EHR) lever 'H' has dropped below the minimum acceptable threshold (typically below 0.5V). This is usually caused by a short to ground in the signal wire, an open circuit in the signal or 5V reference circuit, or a failed potentiometer or Hall-effect sensor inside the EHR lever.
Applies to these machines
5 machines- MAGNUM AFS Connect
- Magnum Series
- Steiger / Quadtrac Series
- Puma Series
- Optum Series
Check the cause
Remove the armrest cover and visually inspect the wiring harness leading to EHR lever H for pinched wires, chafing, or disconnected plugs.
Disconnect the lever and inspect the pins for corrosion, moisture, or backed-out terminals.
With the key ON, probe the harness side of the lever connector to verify that there is a steady 5V reference and a good ground.
Perform a swap test by swapping the electrical connection of Lever H with an adjacent lever (e.g., Lever G or Lever 1). If the fault code changes to the new lever's position, the lever itself has failed. If the fault code remains 'EHR lever H voltage low', the issue is in the wiring harness or the ACM itself.
Repair steps
Power Down
Turn off the tractor and disconnect the battery ground cable to prevent electrical spikes.
Disassemble Armrest
Remove the retaining screws holding the upper armrest console cover/bezel in place to expose the EHR lever modules.
Remove the Faulty Lever
Disconnect the electrical pigtail from EHR lever H. Remove the mounting screws or retaining clips securing the lever assembly to the armrest bracket.
Install the New Lever
Seat the replacement lever into the bracket, secure the fasteners, and plug in the electrical connector. Transfer the color-coded cap from the old lever to the new one if the new part does not include it.
Reassemble
Reinstall the armrest cover and reconnect the battery.
Calibration
Perform the EHR Lever Calibration procedure through the tractor's Pro 700/1200 display monitor or using the Case IH Electronic Service Tool (EST). This allows the ACM to learn the new lever's specific minimum, maximum, and neutral voltage values.
Parts you might need
(3)EHR Control Lever
87613725Transfer the colored plastic identifier cap from the old lever to the replacement.
ACM (Armrest Control Module)
84356319Replacement module if the ACM itself is diagnosed as the failure point.
ACM (Armrest Control Module)
48068689Alternative replacement module if the ACM itself is diagnosed as the failure point.
Get help to fix this fault by requesting a quote