Case IH 518569-02 - ACM – ACM: EHR A retract switch circuit fault
Issue description
The controller is detecting an abnormal electrical signal (such as an open circuit, short to ground, or internal switch failure) specifically when the operator pulls/pushes the remote valve paddle into the 'retract' position.
Applies to these machines
5 machines- MAGNUM AFS Connect
- Magnum AFS Connect series
- Steiger AFS Connect series
- Puma series
- Maxxum series
Check the cause
Use the Case IH Electronic Service Tool (EST) or the AFS Pro 1200 display to monitor the live status of the switch (e.g., MFH EHR Switch 1 Retract) and observe if the state changes when the paddle is moved.
Remove the MultiControl Armrest cover and visually inspect the wiring harness leading to the EHR A switch for pinched wires, chafing against the armrest frame, or loose/corroded connector pins.
Swap the EHR A switch with an adjacent, known-good switch (like EHR B). If the fault code changes to the new location, the switch has failed internally. If the code persists on circuit A, the issue lies in the armrest wiring harness or the ACM.
Use a multimeter to check for continuity on the retract circuit of the switch, and verify the reference voltage (typically 2.5V or 5V on the data bus/signal wire) is present at the connector.
Repair steps
Park the machine on a level surface, turn off the engine, and disconnect the battery ground cable to prevent electrical shorts.
Park the machine on a level surface, turn off the engine, and disconnect the battery ground cable to prevent electrical shorts.
Carefully pry or unscrew the top cover/bezel of the MultiControl Armrest to expose the EHR switch bank.
Carefully pry or unscrew the top cover/bezel of the MultiControl Armrest to expose the EHR switch bank.
Locate the EHR A (Remote 1) switch assembly.
Locate the EHR A (Remote 1) switch assembly.
Unplug the electrical connector from the bottom of the faulty EHR switch.
Unplug the electrical connector from the bottom of the faulty EHR switch.
Depress the retaining clips or remove the mounting screws holding the switch in the armrest console and pull the switch out.
Depress the retaining clips or remove the mounting screws holding the switch in the armrest console and pull the switch out.
Insert the replacement EHR switch into the console until it clicks securely into place.
Insert the replacement EHR switch into the console until it clicks securely into place.
Reconnect the electrical harness to the new switch.
Reconnect the electrical harness to the new switch.
Reinstall the armrest cover/bezel.
Reinstall the armrest cover/bezel.
Reconnect the battery, turn the ignition key to the ON position, and use the tractor's display or EST to clear the inactive 518569-02 fault code.
Reconnect the battery, turn the ignition key to the ON position, and use the tractor's display or EST to clear the inactive 518569-02 fault code.
Test the remote valve by pushing the paddle into the extend and retract positions to ensure proper operation and verify the code does not return.
Test the remote valve by pushing the paddle into the extend and retract positions to ensure proper operation and verify the code does not return.
Parts you might need
(2)Remote Control Valve Switch / EHR Switch
87613723Common EHR Control Lever / Switch for Puma/Magnum/T7/T8. Ensure you order the correct switch configuration (individual paddles vs complete 3-spool or 4-spool switch assembly block). Always verify against your specific machine's serial number.
Armrest Control Switch
AS164041APEnsure you order the correct switch configuration. Always verify against your specific machine's serial number.
Get help to fix this fault by requesting a quote