518584-07 - UCM

Case IH 518584-07 - UCM – UCM: Brake assisted steering cut off relay circuit fault

Issue description

The system has detected a circuit fault (such as an open circuit, short, or abnormal resistance) in the relay responsible for cutting off the automated brake-assisted steering system.

Applies to these machines

  • MAGNUM AFS Connect
  • Magnum 180
  • Magnum 200
  • Magnum 220
  • Magnum 240
  • Magnum 250
  • Magnum 280
  • Magnum 310
  • Magnum 340
  • Magnum 380
  • Magnum 400

Check the cause

  1. Locate the brake-assisted steering cut off relay

  2. Inspect the brake-assisted steering wiring harness for physical damage, chafing, or loose connections

  3. Test the relay itself for internal shorts or open circuits

  4. Verify the circuit continuity between the cut off relay and the Universal Control Module (UCM)

Repair steps

  1. Disconnect battery power

    Disconnect battery power before servicing the UCM or relay circuits.

  2. Replace relay

    If the relay is tested and found to be faulty, replace the brake assisted steering cut off relay.

  3. Repair or replace wiring harness

    If the wiring harness is damaged, repair or replace the affected section of the brake-assisted steering harness.

  4. Reconnect power and clear codes

    Reconnect power, clear the UCM fault codes using the Electronic Service Tool (EST), and test the tractor's steering and braking system to ensure the code does not return.

Parts you might need

(4)
  • Brake Assisted Steering Cut Off Relay

  • WIRE HARNESS, BRAKE-ASSISTED STEERING

    55.047.060
  • WIRE HARNESS, BRAKE-ASSISTED STEERING, JUMPER

    55.047.075
  • WIRING, BRAKE-ASSISTED STEERING

    55.047.100

Get help to fix this fault by requesting a quote