Case IH 518584-07 - UCM – UCM: Brake assisted steering cut off relay circuit fault
Issue description
The system has detected a circuit fault (such as an open circuit, short, or abnormal resistance) in the relay responsible for cutting off the automated brake-assisted steering system.
Applies to these machines
11 machines- MAGNUM AFS Connect
- Magnum 180
- Magnum 200
- Magnum 220
- Magnum 240
- Magnum 250
- Magnum 280
- Magnum 310
- Magnum 340
- Magnum 380
- Magnum 400
Check the cause
Locate the brake-assisted steering cut off relay
Inspect the brake-assisted steering wiring harness for physical damage, chafing, or loose connections
Test the relay itself for internal shorts or open circuits
Verify the circuit continuity between the cut off relay and the Universal Control Module (UCM)
Repair steps
Disconnect battery power
Disconnect battery power before servicing the UCM or relay circuits.
Replace relay
If the relay is tested and found to be faulty, replace the brake assisted steering cut off relay.
Repair or replace wiring harness
If the wiring harness is damaged, repair or replace the affected section of the brake-assisted steering harness.
Reconnect power and clear codes
Reconnect power, clear the UCM fault codes using the Electronic Service Tool (EST), and test the tractor's steering and braking system to ensure the code does not return.
Parts you might need
(4)Brake Assisted Steering Cut Off Relay
WIRE HARNESS, BRAKE-ASSISTED STEERING
55.047.060WIRE HARNESS, BRAKE-ASSISTED STEERING, JUMPER
55.047.075WIRING, BRAKE-ASSISTED STEERING
55.047.100
Get help to fix this fault by requesting a quote