518862-06 - BCM

Case IH 518862-06 - BCM – BCM: ATC recirculation box / blend door actuator - over temperature

Issue description

The actuator motor controlling the Automatic Temperature Control (ATC) recirculation or blend door has exceeded its normal operating temperature threshold, likely due to electrical resistance, a short, or physical binding.

Applies to these machines

  • MAGNUM AFS Connect
  • Magnum 400 AFS Connect Tier 3

Check the cause

  1. Perform a thorough visual inspection of the HVAC wiring harness to ensure there are no disconnected wires or obvious electrical faults.

  2. Check the inlet and outlet temperatures of the heater core to confirm they are hot and coolant is flowing properly.

  3. Change the temperature/recirculation settings on the ATC display and observe if the blend door actuator operates at all.

  4. Remove the actuator from the housing and manually move the blend door. Ensure the door operates smoothly without binding, as a physically stuck door will cause the actuator motor to overwork and overheat.

  5. Check for proper power and ground at the blend door actuator connector. If both are present but the actuator does not move or overheats, the actuator itself is at fault.

Repair steps

  1. Access HVAC box

    Gain access to the HVAC box by removing the glove box or interior cab access panels.

  2. Locate actuator

    Locate the over-temperature ATC blend door/recirculation actuator.

  3. Disconnect harness

    Disconnect the electrical wiring harness from the actuator.

  4. Remove actuator

    Remove the retaining screws holding the actuator in place, and detach the actuator rod assembly to remove the unit.

  5. Install new actuator

    Install the new blend door actuator and secure it with the retaining screws.

  6. Reconnect harness

    Reconnect the electrical harness to the new actuator.

  7. Perform calibration

    Perform an electronic relearn/calibration procedure so the BCM can learn the new actuator's limits and confirm proper operation of the climate control system.

  8. Reassemble cab panels

    Reinstall the glove box and any removed cab panels.

Parts you might need

(6)
  • ATC Recirculation Actuator / HVAC Heater Blend Door Actuator

    Generic replacement part

  • HVAC Actuator

    51445195

    Case IH OEM part

  • Heater Control Valve with Actuator

    87033212

    Fits Case IH Magnum 180, 190, 200, 210, 215, 220, 225, 235, 240

  • Actuator

    275602A1

    Listed as discontinued for older Magnum 215 models, but may be superseded

  • ATC Controller Module

    48185210

    Replace if the BCM/ATC module itself is damaged by the short/over-temp condition

  • ATC Controller Module

    84214115

    Replace if the BCM/ATC module itself is damaged by the short/over-temp condition