518862-12 - BCM

Case IH 518862-12 - BCM – BCM: Sensor regulated power supply (5 V) - short to B+

Issue description

The 5-volt regulated power supply circuit for the sensors is experiencing a short circuit to battery voltage (B+). Note: If the issue is an ATC recirculation box / blend door actuator permanent electrical defect, the correct code is 518502-05.

Applies to these machines

  • MAGNUM AFS Connect
  • Magnum 400 AFS Connect

Check the cause

  1. If diagnosing code 518862-12 (5V short): Test the 5V sensor power supply circuit to locate the short to battery voltage (B+).

  2. If diagnosing code 518502-05 (ATC actuator defect): Inspect the ATC blend door/recirculation actuator and its wiring harness for permanent electrical defects, damaged pins, or melted wires.

Parts you might need

(1)
  • HVAC Heater Blend Door Actuator / ATC Recirculation Actuator

    Applies to the climate control/HVAC system on Case IH Magnum series tractors.

Get help to fix this fault by requesting a quote

Browse other Case IH codes