519044-03 - BCM

Case IH 519044-03 - BCM – BCM: ATC cabin air / A/C evaporator temperature sensor is out of range - high

Issue description

The controller is seeing a voltage signal above the normal operating threshold, most commonly caused by an open circuit, a disconnected sensor, broken wiring, or a short to power.

Applies to these machines

  • MAGNUM AFS Connect
  • CX
  • MX
  • Magnum
  • STX Steiger

Check the cause

  1. Locate the cabin air / evaporator temperature sensor below the operator's seat near the HVAC/evaporator unit

  2. Visually inspect the sensor connections and the wiring harness for physical damage, a loose fit, or corrosion

  3. Test the wiring between the sensor and the BCM for continuity to rule out a broken wire (open circuit) or a short to a power source

Repair steps

  1. Power down the machine and access the evaporator temperature sensor below the operator's seat.

  2. Disconnect the sensor and inspect the pins.

  3. If damage to the sensor circuit or wiring harness is located, repair the wiring problem.

  4. If the wiring and connections test good, the sensor itself has failed internally and must be replaced.

  5. Install the new temperature sensor and reconnect the harness.

  6. Clear all fault codes from the BCM and return the unit to field operation to verify the A/C system functions correctly.