Case IH 519576-11 - UCM – UCM: Steering valve controller calibration fault
Issue description
The system attempted to calibrate the steering valve controller but the procedure failed or the resulting values were out of the acceptable range.
Applies to these machines
5 machines- MAGNUM AFS Connect
- Magnum AFS Connect Series (Models 180, 200, 220, 240, 250, 280, 310, 340, 380, and 400)
- Optum
- Vestrum
- Maxxum
Check the cause
Check Software Versions: Verify that the Steering Valve Controller (SVC) and Universal Control Module (UCM) are running the latest software.
Verify Power and Ground: Check for related voltage fault codes (such as 627-04 or 627-01). Ensure the steering valve is receiving proper battery voltage.
Check CAN Communication: Verify the integrity of the CAN 2 wiring harness for shorts or open circuits between the UCM and steering valve controller.
Repair steps
Connect diagnostic tool
Connect the Case IH Electronic Service Tool (EST) to the machine's diagnostic port.
Clear fault codes
Clear inactive fault codes.
Update software
Flash/update the UCM and Steering Valve Controller (SVC) to the latest software versions if they are outdated.
Run calibration
Rerun the automated Steering Valve Controller Calibration procedure via the EST or the AFS Pro monitor.
Replace hardware
If the calibration fails again (logging 519576-11), the physical steering valve or the steering valve controller hardware may be defective and require replacement.
Parts you might need
(6)Steering Valve Controller (SVC) Software
51631896Software Version 2.02
Steering Valve Controller (SVC) Dataset
51573865Advanced Steering Configuration dataset
Universal Control Module (UCM)
51690151Universal Control Module (UCM)
90342621Universal Control Module (UCM)
47805914Steering Valve / Steering Valve Controller (Hardware)
Get help to fix this fault by requesting a quote